Coolant-Dosing Control System for the Desublimation Apparatus in Uranium Hexafluoride Production; Atomic Energy; Vol. 129, iss. 3
| Parent link: | Atomic Energy Vol. 129, iss. 3.— 2021.— [P. 149-154] |
|---|---|
| Autore principale: | |
| Ente Autore: | |
| Altri autori: | , |
| Riassunto: | Title screen The need to reduce operating costs of commercial uranium hexafluoride production motivates the present study. With this in mind, a variant of coolant flow reduction in the tubing of the desublimation apparatus is proposed. Mathematical calculations showed that the coolant consumption can be reduced by a factor of 2. Field experiments performed at an operating production facility have confirmed the obtained results. A combined control system has been developed to maintain the coolant flow at the minimum level and to secure the conditions of desublimation for uranium hexafluoride. The developed control system will make it possible to reduce by factor of 2 the volume of coolant consumption without loss of product quality or production volume. Режим доступа: по договору с организацией-держателем ресурса |
| Lingua: | inglese |
| Pubblicazione: |
2021
|
| Soggetti: | |
| Accesso online: | https://doi.org/10.1007/s10512-021-00727-6 |
| Natura: | Elettronico Capitolo di libro |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=664579 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 664579 | ||
| 005 | 20250410091059.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\35763 | ||
| 035 | |a RU\TPU\network\33494 | ||
| 090 | |a 664579 | ||
| 100 | |a 20210427d2021 k||y0rusy50 ba | ||
| 101 | 1 | |a eng | |
| 102 | |a US | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Coolant-Dosing Control System for the Desublimation Apparatus in Uranium Hexafluoride Production |f A. V. Nikolaev, N. S. Krinitsyn, V. F. Dyadik | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 9 tit.] | ||
| 330 | |a The need to reduce operating costs of commercial uranium hexafluoride production motivates the present study. With this in mind, a variant of coolant flow reduction in the tubing of the desublimation apparatus is proposed. Mathematical calculations showed that the coolant consumption can be reduced by a factor of 2. Field experiments performed at an operating production facility have confirmed the obtained results. A combined control system has been developed to maintain the coolant flow at the minimum level and to secure the conditions of desublimation for uranium hexafluoride. The developed control system will make it possible to reduce by factor of 2 the volume of coolant consumption without loss of product quality or production volume. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Atomic Energy | ||
| 463 | |t Vol. 129, iss. 3 |v [P. 149-154] |d 2021 | ||
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a электронный ресурс | |
| 700 | 1 | |a Nikolaev |b A. V. |g Aleksandr Valerjevich | |
| 701 | 1 | |a Krinitsyn |b N. S. |g Nikolay Stanislavovich | |
| 701 | 1 | |a Dyadik |b V. F. |c specialist in the field of automatic control systems |c associate Professor of Tomsk Polytechnic University, candidate of technical Sciences |f 1939- |g Valery Feodosievich |3 (RuTPU)RU\TPU\pers\34268 |9 17799 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Инженерная школа ядерных технологий |b Отделение ядерно-топливного цикла |3 (RuTPU)RU\TPU\col\23554 |
| 801 | 2 | |a RU |b 63413507 |c 20210427 |g RCR | |
| 856 | 4 | |u https://doi.org/10.1007/s10512-021-00727-6 | |
| 942 | |c CF | ||