Fluorescent Penetrant Testing by Means of Excilamps

Bibliographische Detailangaben
Parent link:Materials Science Forum: Scientific Journal
Vol. 942 : Modern Problems in Materials Processing, Manufacturing, Testing and Quality Assurance.— 2019.— [P. 141-150]
Körperschaft: Национальный исследовательский Томский политехнический университет Инженерная школа неразрушающего контроля и безопасности Отделение контроля и диагностики
Weitere Verfasser: Kalinichenko A. N. Aleksey Nikolaevich, Sosnin E. A. Eduard Anatoljevich, Avdeev S. M. Sergey Mikhaylovich, Kalinichenko N. P. Nikolay Petrovich, Lobanova I. S. Irina Sergeevna
Zusammenfassung:Title screen
The paper provides a brief review of modern sources of ultraviolet (UV) radiation used in fluorescent penetrant testing (FT). The differences in implementation of the method with different radiation sources (excilamps, mercury UV lamp and LED UV lamp) are revealed experimentally. It is shown that the XeCl excilamp is not inferior to other sources of UV radiation used in FT.
Режим доступа: по договору с организацией-держателем ресурса
Veröffentlicht: 2019
Schlagworte:
Online-Zugang:https://doi.org/10.4028/www.scientific.net/MSF.942.131
Format: Elektronisch Buchkapitel
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=661647