PIN-diode diagnostics of pulsed electron beam for high repetition rate mode
| Parent link: | Journal of Physics: Conference Series Vol. 830 : Energy Fluxes and Radiation Effects 2016.— 2017.— [012044, 5 p.] |
|---|---|
| Main Author: | |
| Corporate Authors: | , |
| Other Authors: | , |
| Summary: | Title screen This work describes the operating principle and test results of the diagnostics for measuring the pulsed electron beam parameters under repetitive operation mode. The diagnostics is based on a PIN-diode, which is used as a bremsstrahlung detector. The signal from a PIN-diode was converted to a pseudo constant voltage signal which can be measured by a conventional voltmeter. Then the signal acquired by the voltmeter was compared with a reference signal indicating the normal operating regime of the accelerator, thus information about the shot-to-shot reproducibility of the electron beam parameters was given. The system was developed and tested for the ASTRA-M accelerator with the following operating parameters: 470 kV accelerating voltage, 120 ns beam duration and up to 50 pulses per second repetition rate. |