Arcless opening of direct current circuits in technical systems
Parent link: | Journal of Physics: Conference Series Vol. 803 : Information Technologies in Business and Industry (ITBI2016).— 2017.— [012123, 5 p.] |
---|---|
Autor principal: | |
Altres autors: | , |
Sumari: | Title screen Operation of the proposed DC circuit breaker consists in the fact that the closing of the thyristor in the DC power circuit with an inductive load results from opening the auxiliary circuit with a current value several fold less than the load current. The power and auxiliary circuits are connected by means of a current transformer having counter switch windings. After switching, the load is shunted by a diode and does not affect the transition process. Simulations and experimental tests of the DC circuit breaker model showed its performance capability, and the breaker can be used for switching in existing DC high current circuits with inductive loads. |
Idioma: | anglès |
Publicat: |
2017
|
Matèries: | |
Accés en línia: | http://dx.doi.org/10.1088/1742-6596/803/1/012123 http://earchive.tpu.ru/handle/11683/38180 |
Format: | Electrònic Capítol de llibre |
KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=654407 |