Simulation and optimization of dummy loads for microwave calorimeters

Bibliographic Details
Parent link:Telecommunications Forum (TELFOR 2014): Proceedings of 22nd forum, November 25-27 2014, Belgrade, Serbia. [4 p.].— , 2014
Main Author: Kozhevnikov V. Yu. Vasily Yurevich
Corporate Author: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра электроэнергетических систем (ЭЭС)
Other Authors: Klimov A. I. Aleksey Ivanovich, Kozyrev A. V. Alexey Vladimirovich
Summary:Title screen
A two-dimensional finite-difference time-domain method with uniaxial perfectly matched layers was applied to analysis of a three-layer wide-aperture microwave calorimeter. The method was shown to be an efficient tool for calculating the optimum geometric parameters of a semi-infinite model dummy load. Using the time-domain results, the frequency-dependent transmission/reflection coefficients of the load were calculated for normal incidence of a monochromatic plane wave at operating frequencies range of 1-12 GHz for the first time.
Режим доступа: по договору с организацией-держателем ресурса
Published: 2014
Subjects:
Online Access:https://doi.org/10.1109/TELFOR.2014.7034536
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=653596