Superheater Tube Flat Wall Stationary Temperature Field

Detalles Bibliográficos
Parent link:MATEC Web of Conferences
Vol. 72 : Heat and Mass Transfer in the System of Thermal Modes of Energy – Technical and Technological Equipment (HMTTSC-2016).— 2016.— [01084, 6 p.]
Autor principal: Parpiev A. T.
Autor Corporativo: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра теоретической и промышленной теплотехники (ТПТ)
Otros Autores: Loginov V. S. Vladimir Stepanovich
Sumario:Title screen
The BKZ-220-100-9 steam generator platen superheater tube flat wall stationary temperature fields analysis have been made. The six steel grades, using in boiler fabrication, namely, St. 10, St. 20, 12H1MF, 15HM, 1H18N9T and 12H18N12T, have been used. The temperature curves calculation has been made by using outer and inner surface heat-transfer coefficients nine different combinations.
Lenguaje:inglés
Publicado: 2016
Materias:
Acceso en línea:http://dx.doi.org/10.1051/matecconf/20167201084
http://earchive.tpu.ru/handle/11683/33470
Formato: Electrónico Capítulo de libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=649946

Ejemplares similares