| Summary: | Title screen The BKZ-220-100-9 steam generator platen superheater tube flat wall stationary temperature fields analysis have been made. The six steel grades, using in boiler fabrication, namely, St. 10, St. 20, 12H1MF, 15HM, 1H18N9T and 12H18N12T, have been used. The temperature curves calculation has been made by using outer and inner surface heat-transfer coefficients nine different combinations. |