Influence of Radiation and Convective Types of Heat Exchange on the Necessary Duration of Temperature Measurement by Thermocouples
| Parent link: | MATEC Web of Conferences Vol. 72 : Heat and Mass Transfer in the System of Thermal Modes of Energy – Technical and Technological Equipment (HMTTSC-2016).— 2016.— [01005, 5 p.] |
|---|---|
| Main Author: | |
| Corporate Author: | |
| Other Authors: | , |
| Summary: | Title screen Results of research of influence of radiation heat exchange on duration of execution of measurement high temperatures are given by thermocouples, influence of the free convection on results of temperature measurement is also considered by the thermocouples set in protective sleeves with a gap. Researches showed that radiation heat exchange leads to lowering of duration of heating of the thermocouple to 30% whereas the free convection in a protective sleeve practically doesn't exert impact on process of heating up of the sensor. |
| Published: |
2016
|
| Subjects: | |
| Online Access: | http://dx.doi.org/10.1051/matecconf/20167201005 http://earchive.tpu.ru/handle/11683/33462 |
| Format: | Electronic Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=649870 |