Clinical Efficiency of Absorbing Wound Dressing Consisting of Nanostructured Graphite in Comparison with Other Modern Dressings; The 7th International Forum on Strategic Technology (IFOST-2012), September 18-21, 2012, Tomsk

書誌詳細
Parent link:The 7th International Forum on Strategic Technology (IFOST-2012), September 18-21, 2012, Tomsk.— 2012.— [5 p.]
第一著者: Shteynle А. V. Aleksandr Vladimirovich
団体著者: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Кафедра экологии и безопасности жизнедеятельности (ЭБЖ)
要約:Title screen
This research is focused on the study of absorbing capacity and absorbency of an absorbent wound dressing made of nanostructured graphite as compared with other state-of-the-art types of dressing. Absorbing capacity and absorbency of two types of wound dressings based on nanostructured graphite were studied according to the method by Yu. Abaev in comparison with modern dressings made by various producers. Wound dressing made of nanostructured graphite can effectively evacuate wound discharge providing a “vertical drainage” only, contain wound discharge in the sorption layer for a long time preventing its desorption in the wound and penetrating onto skin.
Режим доступа: по договору с организацией-держателем ресурса
言語:英語
出版事項: 2012
主題:
オンライン・アクセス:http://dx.doi.org/10.1109/IFOST.2012.6357596
フォーマット: 電子媒体 図書の章
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=647647

MARC

LEADER 00000nla2a2200000 4500
001 647647
005 20231101134458.0
035 |a (RuTPU)RU\TPU\network\12793 
035 |a RU\TPU\network\11926 
090 |a 647647 
100 |a 20160419a2012 k y0engy50 ba 
101 0 |a eng 
105 |a a z 101zy 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Clinical Efficiency of Absorbing Wound Dressing Consisting of Nanostructured Graphite in Comparison with Other Modern Dressings  |f А. V. Shteynle 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 6 tit.] 
330 |a This research is focused on the study of absorbing capacity and absorbency of an absorbent wound dressing made of nanostructured graphite as compared with other state-of-the-art types of dressing. Absorbing capacity and absorbency of two types of wound dressings based on nanostructured graphite were studied according to the method by Yu. Abaev in comparison with modern dressings made by various producers. Wound dressing made of nanostructured graphite can effectively evacuate wound discharge providing a “vertical drainage” only, contain wound discharge in the sorption layer for a long time preventing its desorption in the wound and penetrating onto skin. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
463 0 |0 (RuTPU)RU\TPU\network\10411  |t The 7th International Forum on Strategic Technology (IFOST-2012), September 18-21, 2012, Tomsk  |o [proceedings]  |f National Research Tomsk Polytechnic University (TPU)  |v [5 p.]  |d 2012 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
700 1 |a Shteynle  |b А. V.  |c Specialist in the field of medical technology  |c Associate Professor of Tomsk Polytechnic University  |c Associate Professor Siberian State Medical University, Candidate of medical Sciences  |f 1967-  |g Aleksandr Vladimirovich  |2 stltpush  |3 (RuTPU)RU\TPU\pers\36576 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт неразрушающего контроля (ИНК)  |b Кафедра экологии и безопасности жизнедеятельности (ЭБЖ)  |h 4850  |2 stltpush  |3 (RuTPU)RU\TPU\col\18720 
801 2 |a RU  |b 63413507  |c 20160419  |g RCR 
856 4 |u http://dx.doi.org/10.1109/IFOST.2012.6357596 
942 |c CF