Device CAP-10 for in-process measurement of the single-core wire capacitance per unit length

Bibliografiske detaljer
Parent link:Recent Advances on Systems, Signals, Control, Communications and Computers, December 12-14, 2015, Budapest, Hungary.— 2015.— [P. 272-277]
Hovedforfatter: Goldstein (Goldshtein) A. E. Aleksandr Efremovich
Institution som forfatter: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Кафедра физических методов и приборов контроля качества (ФМПК)
Andre forfattere: Vavilova G. V. Galina Vasilievna
Summary:Title screen
The paper describes an electrical-capacitive method to perform in-process measurement thecapacitance of a single-core electric wire per unit length during its insulating. The optimum designvalues of the electro-capacitive measuring transducer are selected to minimize the impact of thedesign parametrs, and insulation and water properties. The block diagram of the device CAP-10developed for implementation of the proposed method is presented. An algorithm for digitalconversion of the output signal of the electro-capacitive measuring transducer enables correction ofthe effect of the change in water conductivity. Technical implementation of the device is described.
Sprog:engelsk
Udgivet: 2015
Fag:
Online adgang:http://www.wseas.us/e-library/conferences/2015/Budapest/DNCOSE/DNCOSE-43.pdf
Format: Electronisk Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=646912