Investigation of Lamb Wave Based Ultrasonic Technique for AA2024 Evaluation at Static Tensile Loading

Bibliografski detalji
Parent link:Key Engineering Materials: Scientific Journal
Vol. 685 : High Technology: Research and Applications 2015 (HTRA 2015).— 2016.— [P. 394-398]
Autor kompanije: Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Кафедра материаловедения в машиностроении (ММС)
Daljnji autori: Byakov A. V. Anton Viktorovich, Eremin A. V. Alexandr Vyacheslavovich, Burkov M. V. Mikhail Vladimirovich, Shah R. T., Lyubutin P. S. Pavel Stepanovich, Panin S. V. Sergey Viktorovich
Sažetak:Title screen
In the paper the results of Lamb wave ultrasonic technique for evaluation of AA2024T3 specimens during tensile testing are presented. Three piezoelectric transducers (PZT) used as an actuator and two sensors were glued on the specimen surface using epoxy adhesive. Two frequencies of testing signals (50 kHz and 335 kHz) were used. The set of static tensile tests were performed. The recorded signals were processed to calculate the informative parameters to evaluate the changes of the stress-strain state of the specimen and its microstructure.
Режим доступа: по договору с организацией-держателем ресурса
Jezik:engleski
Izdano: 2016
Serija:Mechanical Engineering Technology
Teme:
Online pristup:http://dx.doi.org/10.4028/www.scientific.net/KEM.685.394
Format: Elektronički Poglavlje knjige
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=646450