Numerical Research of the Measurement Error of Temperature Thermocouples with the Isolated Seal; MATEC Web of Conferences; Vol. 23 : Heat and Mass Transfer in the Thermal Control System of Technical and Technological Energy Equipment

Xehetasun bibliografikoak
Parent link:MATEC Web of Conferences
Vol. 23 : Heat and Mass Transfer in the Thermal Control System of Technical and Technological Energy Equipment.— 2015.— [01017, 5 p.]
Egile nagusia: Atroshenko Yu. K. Yuliana Konstantinovna
Erakunde egilea: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра автоматизации теплоэнергетических процессов (АТП)
Beste egile batzuk: Bychkova A. A. Alena, Strizhak P. A. Pavel Alexandrovich
Gaia:Title screen
Mathematical models of heattransfer are developed for an assessment of measurement errors of temperature by thermocouples with an isolated and uninsulated seal. Dependences of necessary time of heating (for authentic measurement) for the thermocouples with an isolated seal manufactured of different materials are set. It is shown that for thermocouples with isolated seal minimum necessary duration of heating up slightly exceeds this index for thermocouples with an uninsulated seal.
Hizkuntza:ingelesa
Argitaratua: 2015
Gaiak:
Sarrera elektronikoa:http://dx.doi.org/10.1051/matecconf/20152301017
http://earchive.tpu.ru/handle/11683/15368
Formatua: Baliabide elektronikoa Liburu kapitulua