Analysis based on the diffusion model for saturation silica gel with water vapor at conservation units steam circuit TPP; European Physical Journal Web of Conferences (EPJ Web of Conferences); Vol. 82 : Thermophysical Basis of Energy Technologies
| Parent link: | European Physical Journal Web of Conferences (EPJ Web of Conferences) Vol. 82 : Thermophysical Basis of Energy Technologies.— 2015.— [01032, 3 р.] |
|---|---|
| Hovedforfatter: | |
| Institution som forfatter: | |
| Andre forfattere: | |
| Summary: | Title screen A quantitative analysis of the diffusion model dehumidifying air in the steam circuit of TPP, with a layer of silica gel. Showed that such an approximation, supplemented the experimental value of the coefficient of free diffusion identified by the developed method gives reliable values for the concentration of water vapor absorption over time. |
| Sprog: | engelsk |
| Udgivet: |
2015
|
| Fag: | |
| Online adgang: | http://dx.doi.org/10.1051/epjconf/20158201032 |
| Format: | Electronisk Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=643114 |