Analysis based on the diffusion model for saturation silica gel with water vapor at conservation units steam circuit TPP
Parent link: | European Physical Journal Web of Conferences (EPJ Web of Conferences) Vol. 82 : Thermophysical Basis of Energy Technologies.— 2015.— [01032, 3 р.] |
---|---|
প্রধান লেখক: | |
অন্যান্য লেখক: | |
সংক্ষিপ্ত: | Title screen A quantitative analysis of the diffusion model dehumidifying air in the steam circuit of TPP, with a layer of silica gel. Showed that such an approximation, supplemented the experimental value of the coefficient of free diffusion identified by the developed method gives reliable values for the concentration of water vapor absorption over time. |
ভাষা: | ইংরেজি |
প্রকাশিত: |
2015
|
বিষয়গুলি: | |
অনলাইন ব্যবহার করুন: | http://dx.doi.org/10.1051/epjconf/20158201032 |
বিন্যাস: | বৈদ্যুতিক গ্রন্থের অধ্যায় |