Determination of enamel insulation corona resistance by high-frequency modulated pulses
| Parent link: | IOP Conference Series: Materials Science and Engineering Vol. 81 : Radiation-Thermal Effects and Processes in Inorganic Materials.— 2015.— [012094, 7 p.] |
|---|---|
| Corporate Authors: | , |
| Other Authors: | , , , |
| Summary: | Title screen In the article test equipment is described for corona resistance testing of enameled winding wire samples. The primary element of equipment is generator producing test voltage with necessary waveform and magnitude according to the required PWM. Test conditions are accurately simulated by operational loads on a winding insulation (simultaneous impact of temperature and corona discharges). Obtained results of average time to breakdown show that the enamel insulation modified by silicon nanoparticles has a maximum corona resistance. Режим доступа: по договору с организацией-держателем ресурса |
| Published: |
2015
|
| Subjects: | |
| Online Access: | http://dx.doi.org/10.1088/1757-899X/81/1/012094 http://earchive.tpu.ru/handle/11683/14737 |
| Format: | Electronic Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=643023 |