Synchronization of energy extraction from microwave compressor cavities with laser triggering

Bibliographic Details
Parent link:The 7th International Forum on Strategic Technology (IFOST-2012), September 18-21, 2012, Tomsk: [proceedings]/ National Research Tomsk Polytechnic University (TPU). [2 p.].— , 2012
Corporate Author: Национальный исследовательский Томский политехнический университет (ТПУ) Физико-технический институт (ФТИ) Лаборатория № 46
Other Authors: Arteev M. S. Mikhail Sidorovich, Avgustinovich V. A. Vladimir Andreevich, Artemenko S. N. Sergey Nikolaevich, Kaminsky V. L. Valery Ludvigovich, Novikov S. A. Sergey Avtonomovich, Yushkov Y. G. Yuri Georgievich
Summary:Title screen
Laser triggering was used to synchronize the switching of two resonant microwave compressors over to energy extraction mode. The obtained experimental data of the study are presented. Practically the precise synchronism was demonstrated when switching the working mode in the storage regime. Each compressor provided pulses of 250 MW power and 5 ns pulsewidth, the pulse summation gave the output pulse power of 500 MW. Foundation of the supposition that the combined power of several compressors with common load can exceed 1 GW when laser radiation synchronized operation is given.
Режим доступа: по договору с организацией-держателем ресурса
Published: 2012
Subjects:
Online Access:http://dx.doi.org/10.1109/IFOST.2012.6357777