Detecting corrosion in thick metals by applying active IR thermography
| Parent link: | Thermal Infrared Applications XXXIV, April 23-26, 2012: Proc. SPIE 8354. [9 p.].— , 2012 |
|---|---|
| Main Author: | |
| Other Authors: | |
| Summary: | Title screen Both theoretical and experimental results obtained by applying active infrared thermography to the inspection of hidden corrosion in 1-10 mm thick steel samples are presented. The emphasis is put on the comparison of heating and data processing techniques.© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only Режим доступа: по договору с организацией-держателем ресурса |
| Published: |
2012
|
| Subjects: | |
| Online Access: | http://dx.doi.org/10.1117/12.920321 |
| Format: | Electronic Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=636986 |