Determination of the influence zone on the atmospheric pollution of chemical elements from a point source (Combined heat and power)

Bibliographic Details
Parent link:IFOST 2012: The 7th International Forum on Strategic Techology, September 17-21, 2012, Tomsk/ National Research Tomsk Polytechnic University (TPU).— , 2012
Vol. 1.— 2012.— P. 137-141
Main Author: Ryzhakova (Rizhakova) N. K. Nadezhda Kirillovna
Other Authors: Rogova N. S. Natalya Sergeevna, Pokrovskaya E. A. Elena Aleksandrovna
Summary:Semi-empirical transfer model of chemical contaminants in the atmosphere from a point source is considered in the report. The model is based on solving the diffusivity equation that takes account of thetransport of impurities in the horizontal direction due to wind, turbulent diffusion and gravitational deposition in a vertical direction. In the report it is suggested to determine the modeling parameters by measurements of atmospheric pollution at several points. These points are selected in a particular direction. Epiphytic mosses are used as depositing of pollution objects. Chemical elements concentrations are determined with the help of neutron activation analysis. The considered model is used to estimate the influence zone of a point source on the basis of thermal power plant (TPP-5 Novosibirsk).
Published: 2012
Series:Section 1. Chemical engineering and "Green technology"
Subjects:
Format: Book Chapter