Methanol Solution Recuperation at Gas Distillate Production

Bibliographic Details
Parent link:13 International symposium on high current electronics: Tomsk, Russia, 25-29 July 2004/ edited by B. Kovalchuk, G. Remnev. [P. 442-443].— , 2004
Other Authors: Lopatin V. V. Vladimir Vasilyevich, Medvedev Y. V., Sekisov F. G., Shubin B. G., Shubin M. B.
Summary:Title from the title-page.
Two-stage scheme is represented for purify industrial wastewater from methanol: industrial wastewater separation in the vacuum evaporator to the condensate fluid with methanol concentration of 80-90% and vat residue with concentration of 4-6%; after treatment of vat residue by electric discharge method down to the maximum permissible concentration level. The solution separated effectiveness is characterized by the following energy inputs: 2.16 kJ/l (first stage) and 2.18 kJ/g (second stage).
Режим доступа: из корпоративной сети ТПУ
Text files
Published: 2004
Series:Pulsed power applications
Subjects:
Online Access:http://www.lib.tpu.ru/fulltext2/c/2004/C13/024.pdf
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=231805