Mathematical modeling of heat and mass transfer during evaporation of saline solutions: Single droplet, droplet group, and spray; International Journal of Heat and Mass Transfer; Vol. 266

Opis bibliograficzny
Parent link:International Journal of Heat and Mass Transfer.— .— Amsterdam: Elsevier Science Publishing Company Inc.
Vol. 266.— 2026.— Article number 128884, 19 p.
Kolejni autorzy: Mikulich A. V. Anastasiya Vyacheslavovna, Antonov D. V. Dmitry Vladimirovich, Kuznetsov G. V. Geny Vladimirovich, Strizhak P. A. Pavel Alexandrovich
Streszczenie:Title screen
The problem of freshwater scarcity is becoming increasingly acute in the modern world. Thermal methods provide high efficiency in terms of the specific volume of purified water obtained; however, they require substantial energy input associated with fuel combustion to ensure phase transformations of contaminated liquids. The issue of energy efficiency is particularly critical in the case of salt solutions. In the present study, a predictive mathematical framework is developed to enable rational control of the energy load in heating chambers used for thermal desalination. The framework describes heat and mass transfer processes during evaporation of salt solution droplets and includes an algorithm for solving the coupled system of equations governing energy transfer, diffusion of solution components in the liquid phase during salt crystallization, and the motion of salt solution droplets within a spray. The results of experimental and theoretical investigations of water evaporation characteristics from salt solution droplets are presented, using NaCl, NH₄Cl, and CuSO₄ solutions as representative examples. The initial salt concentrations ranged from 1 to 20 wt.%. Low salt concentrations (up to 5 wt.%) correspond to salinity levels typical of seas and oceans, whereas higher concentrations (up to 20 wt.%) are characteristic of salt solutions encountered in thermal liquid treatment units at specific industrial stages. The connection of high-temperature and solar driven interfacial droplet evaporation and discussed. A concept for transferring modeling results from single droplets to a spray is proposed. Practical recommendations are formulated to achieve maximum efficiency of thermal desalination processes in heating chambers in terms of evaporation time and energy consumption
Текстовый файл
AM_Agreement
Język:angielski
Wydane: 2026
Hasła przedmiotowe:
Dostęp online:https://doi.org/10.1016/j.ijheatmasstransfer.2026.128884
Format: Elektroniczne Rozdział
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=686542

MARC

LEADER 00000naa0a2200000 4500
001 686542
005 20260519141640.0
090 |a 686542 
100 |a 20260519d2026 k||y0rusy50 ba 
101 0 |a eng 
102 |a NL 
135 |a drcn ---uucaa 
181 0 |a i   |b  e  
182 0 |a b 
183 0 |a cr  |2 RDAcarrier 
200 1 |a Mathematical modeling of heat and mass transfer during evaporation of saline solutions: Single droplet, droplet group, and spray  |f A. V. Mikulich, D. V. Antonov, G. V. Kuznetsov, P. A. Strizhak 
203 |a Текст  |b визуальный  |c электронный 
283 |a online_resource  |2 RDAcarrier 
300 |a Title screen 
320 |a References: 50 tit 
330 |a The problem of freshwater scarcity is becoming increasingly acute in the modern world. Thermal methods provide high efficiency in terms of the specific volume of purified water obtained; however, they require substantial energy input associated with fuel combustion to ensure phase transformations of contaminated liquids. The issue of energy efficiency is particularly critical in the case of salt solutions. In the present study, a predictive mathematical framework is developed to enable rational control of the energy load in heating chambers used for thermal desalination. The framework describes heat and mass transfer processes during evaporation of salt solution droplets and includes an algorithm for solving the coupled system of equations governing energy transfer, diffusion of solution components in the liquid phase during salt crystallization, and the motion of salt solution droplets within a spray. The results of experimental and theoretical investigations of water evaporation characteristics from salt solution droplets are presented, using NaCl, NH₄Cl, and CuSO₄ solutions as representative examples. The initial salt concentrations ranged from 1 to 20 wt.%. Low salt concentrations (up to 5 wt.%) correspond to salinity levels typical of seas and oceans, whereas higher concentrations (up to 20 wt.%) are characteristic of salt solutions encountered in thermal liquid treatment units at specific industrial stages. The connection of high-temperature and solar driven interfacial droplet evaporation and discussed. A concept for transferring modeling results from single droplets to a spray is proposed. Practical recommendations are formulated to achieve maximum efficiency of thermal desalination processes in heating chambers in terms of evaporation time and energy consumption 
336 |a Текстовый файл 
371 0 |a AM_Agreement 
461 1 |t International Journal of Heat and Mass Transfer  |c Amsterdam  |n Elsevier Science Publishing Company Inc. 
463 1 |t Vol. 266  |v Article number 128884, 19 p.  |d 2026 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a Thermal desalination of liquids 
610 1 |a High-temperature evaporation 
610 1 |a Single droplet 
610 1 |a Spray 
610 1 |a Salt solution 
610 1 |a salts 
701 1 |a Mikulich  |b A. V.  |g Anastasiya Vyacheslavovna 
701 1 |a Antonov  |b D. V.  |c specialist in the field of heat and power engineering  |c Associate Professor, Research Engineer at Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences  |f 1996-  |g Dmitry Vladimirovich  |9 22322 
701 1 |a Kuznetsov  |b G. V.  |c Specialist in the field of heat power energy  |c Professor of Tomsk Polytechnic University, Doctor of Physical and Mathematical Sciences  |f 1949-  |g Geny Vladimirovich  |9 15963 
701 1 |a Strizhak  |b P. A.  |c Specialist in the field of heat power energy  |c Doctor of Physical and Mathematical Sciences (DSc), Professor of Tomsk Polytechnic University (TPU)  |f 1985-  |g Pavel Alexandrovich  |9 15117 
801 0 |a RU  |b 63413507  |c 20260519 
850 |a 63413507 
856 4 0 |u https://doi.org/10.1016/j.ijheatmasstransfer.2026.128884  |z https://doi.org/10.1016/j.ijheatmasstransfer.2026.128884 
942 |c CF