Application of integral radiobiological criteria for qualitative comparison of remote radiotherapy technologies in the treatment of prostate tumors

Podrobná bibliografie
Parent link:Biomedical Engineering=Медицинская техника.— .— New York: Springer Science+Business Media LLC.— 0025-8075
Vol. 58, iss. 5.— 2025.— P. 357-361
Další autoři: Sutygina Y. N. Yana Nikolaevna, Sukhikh E. S. Evgeniya Sergeevna, Stakhova O. M. Olga Mikhailovna, Belykh A. A. Anastasiya Anatoljevna, Brazovsky K. S. Konstantin Stanislavovich, Novoselov K. I. Konstantin Ivanovich
Shrnutí:Title screen
This paper presents the TCP/NTCP Calculator software, developed in Russia, for determination of optimal dosimetric treatment plans using five patients diagnosed with prostate cancer as an example. The dosimetric planning system was used to create three variants of individual dosimetric plans for each patient using a variety of remote methods of delivering the absorbed dose: three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy with static (IMRT) and rotational (VMAT) irradiation
Текстовый файл
AM_Agreement
Jazyk:angličtina
Vydáno: 2025
Témata:
On-line přístup:https://doi.org/10.1007/s10527-024-10433-9
Статья на русском языке
Médium: Elektronický zdroj Kapitola
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=682833

MARC

LEADER 00000naa0a2200000 4500
001 682833
005 20251105153128.0
090 |a 682833 
100 |a 20251105d2025 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i   |b  e  
182 0 |a b 
183 0 |a cr  |2 RDAcarrier 
200 1 |a Application of integral radiobiological criteria for qualitative comparison of remote radiotherapy technologies in the treatment of prostate tumors  |d Применение интегральных радиобиологических критериев для качественного сравнения технологий дистанционной лучевой терапии в лечении опухоли предстательной железы  |z rus  |f Ya. N. Sutygina, E. S. Sukhikh, O. M. Stakhova [et al.] 
203 |a Текст  |c электронный  |b визуальный 
283 |a online_resource  |2 RDAcarrier 
300 |a Title screen 
320 |a References: 14 tit 
330 |a This paper presents the TCP/NTCP Calculator software, developed in Russia, for determination of optimal dosimetric treatment plans using five patients diagnosed with prostate cancer as an example. The dosimetric planning system was used to create three variants of individual dosimetric plans for each patient using a variety of remote methods of delivering the absorbed dose: three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy with static (IMRT) and rotational (VMAT) irradiation 
336 |a Текстовый файл 
371 0 |a AM_Agreement 
461 1 |t Biomedical Engineering  |l Медицинская техника  |c New York  |n Springer Science+Business Media LLC  |x 0025-8075 
463 1 |t Vol. 58, iss. 5  |v P. 357-361  |d 2025 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
701 1 |a Sutygina  |b Y. N.  |c specialist in the field of nuclear technologies  |c engineer of Tomsk Polytechnic University  |f 1995-  |g Yana Nikolaevna  |9 23112 
701 1 |a Sukhikh  |b E. S.  |c specialist in the field of nuclear energy  |c Associate Professor of Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences  |f 1986-  |g Evgeniya Sergeevna  |9 15411 
701 1 |a Stakhova  |b O. M.  |c specialist in the field of nuclear technologies  |c engineer of Tomsk Polytechnic University  |f 1998-  |g Olga Mikhailovna  |9 23110 
701 1 |a Belykh  |b A. A.  |g Anastasiya Anatoljevna 
701 1 |a Brazovsky  |b K. S.  |g Konstantin Stanislavovich 
701 1 |a Novoselov  |b K. I.  |g Konstantin Ivanovich 
801 0 |a RU  |b 63413507  |c 20251105  |g RCR 
856 4 |u https://doi.org/10.1007/s10527-024-10433-9  |z https://doi.org/10.1007/s10527-024-10433-9 
856 4 |u http://www.mtjournal.ru/archive/2024/meditsinskaya-tekhnika-5/primenenie-integralnykh-radiobiologicheskikh-kriteriev-dlya-kachestvennogo-sravneniya-tekhnologiy-di  |z Статья на русском языке 
942 |c CF