Новые электрохимические сенсоры для вольтамперометрического определения интерферонов; Перспективы развития фундаментальных наук; Т. 2 : Химия
| Parent link: | Перспективы развития фундаментальных наук=Prospects of Fundamental Sciences Development: сборник научных трудов XХII Международной конференции студентов, аспирантов и молодых ученых, г. Томск, 22-25 апреля 2025/ Национальный исследовательский Томский политехнический университет ; под ред. И. А. Курзиной [и др.].— .— Томск: Изд-во ТПУ Т. 2 : Химия.— 2025.— С. 211-213 |
|---|---|
| Autor Principal: | |
| Outros autores: | |
| Summary: | Заглавие с экрана In this paper, we consider the possibility of using the voltammetric method to determine alpha- and gamma-interferon using an analytical complex that includes a polarizable working electrode, an auxiliary electrode, and a non-polarizable reference electrode. Traditional carbon electrodes used to determine organic compounds do not have sufficient sensitivity to analyze interferons in biological environments, which necessitated modifying the surface of the working glass carbon electrode. The auxiliary and reference electrodes were made on the basis of silver chloride. To increase the sensitivity of interferon determination, a carbon electrode with a modified surface is proposed. Gold and aryldiazonium salts with a carboxyl group were used as modifiers. The use of such an organo-modified electrode provided clear signals of alpha- and gamma-interferons in a background phosphate buffer solution with pH 9.18. The analysis results showed a linear dependence of the peak height on the concentration of interferons. It was also found that the maximum peak height is observed at the accumulation potential of –0.6 V. Optimization of the analysis conditions, such as the electrode material, accumulation potential, accumulation time and composition of the Electrolyte backgrounds, was successfully carried out. The use of gold for electrode modification is presented as one of the ways to increase the sensitivity of the method Текстовый файл |
| Idioma: | ruso |
| Publicado: |
2025
|
| Subjects: | |
| Acceso en liña: | http://earchive.tpu.ru/handle/11683/132873 |
| Formato: | MixedMaterials Electrónico Capítulo de libro |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=682503 |
MARC
| LEADER | 00000naa2a2200000 4500 | ||
|---|---|---|---|
| 001 | 682503 | ||
| 005 | 20251103141928.0 | ||
| 090 | |a 682503 | ||
| 100 | |a 20251021d2025 k||y0rusy50 ca | ||
| 101 | 0 | |a rus | |
| 102 | |a RU | ||
| 135 | |a drcn ---uucaa | ||
| 200 | 1 | |a Новые электрохимические сенсоры для вольтамперометрического определения интерферонов |d New electrochemical sensors for voltammetric determination of interferons |f А. А. Нурмаметова |g науч. рук. Г. Б. Слепченко |z eng | |
| 300 | |a Заглавие с экрана | ||
| 330 | |a In this paper, we consider the possibility of using the voltammetric method to determine alpha- and gamma-interferon using an analytical complex that includes a polarizable working electrode, an auxiliary electrode, and a non-polarizable reference electrode. Traditional carbon electrodes used to determine organic compounds do not have sufficient sensitivity to analyze interferons in biological environments, which necessitated modifying the surface of the working glass carbon electrode. The auxiliary and reference electrodes were made on the basis of silver chloride. To increase the sensitivity of interferon determination, a carbon electrode with a modified surface is proposed. Gold and aryldiazonium salts with a carboxyl group were used as modifiers. The use of such an organo-modified electrode provided clear signals of alpha- and gamma-interferons in a background phosphate buffer solution with pH 9.18. The analysis results showed a linear dependence of the peak height on the concentration of interferons. It was also found that the maximum peak height is observed at the accumulation potential of –0.6 V. Optimization of the analysis conditions, such as the electrode material, accumulation potential, accumulation time and composition of the Electrolyte backgrounds, was successfully carried out. The use of gold for electrode modification is presented as one of the ways to increase the sensitivity of the method | ||
| 336 | |a Текстовый файл | ||
| 461 | 1 | |0 682243 |t Перспективы развития фундаментальных наук |l Prospects of Fundamental Sciences Development |o сборник научных трудов XХII Международной конференции студентов, аспирантов и молодых ученых, г. Томск, 22-25 апреля 2025 |9 682243 |c Томск |n Изд-во ТПУ |f Национальный исследовательский Томский политехнический университет ; под ред. И. А. Курзиной [и др.] | |
| 463 | 1 | |0 682251 |9 682251 |t Т. 2 : Химия |d 2025 |u conference_tpu-2025-C21_V2.pdf |v С. 211-213 |l Vol. 2 : Chemistry | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a interferon | |
| 610 | 1 | |a stripping voltammetry | |
| 610 | 1 | |a glassy carbon electrode | |
| 610 | 1 | |a modifier | |
| 700 | 1 | |a Нурмаметова |b А. А. | |
| 702 | 1 | |a Слепченко |b Г. Б. |c химик |c профессор Томского политехнического университета, доктор химических наук |f 1956- |g Галина Борисовна |4 727 | |
| 801 | 0 | |a RU |b 63413507 |c 20251021 |g RCR | |
| 856 | 4 | |z http://earchive.tpu.ru/handle/11683/132873 |u http://earchive.tpu.ru/handle/11683/132873 | |
| 942 | |c CF | ||