State estimation of power system mode parameters by telemetry and synchronized phasor measurements

Λεπτομέρειες βιβλιογραφικής εγγραφής
Parent link:Eurasian Physical Technical Journal.— .— Karaganda: KarSU
Vol. 21, No. 4 (50).— 2024.— P. 61-70
Κύριος συγγραφέας: Batseva N. L. Natalya Lenmirovna
Συγγραφή απο Οργανισμό/Αρχή: National Research Tomsk Polytechnic University (570)
Άλλοι συγγραφείς: Foos Yu. A. Yuliya Alekseevna
Περίληψη:Title screen
Real time hardware and software systems are operated at centers of a power system operation. The key unit of these systems is the state estimation block since, based on the results of mode parameters derived from this block, parameters that are more comprehensive can be calculated. These parameters are considered for system stability and reliability. Currently, not only telemetry but also synchronized phasor measurements can be used for a state estimation. Therefore, the development of state estimation methods is the relevant task. The proposed method allows improving the estimation accuracy and the quality of decisions, related to system stability and reliability. The method is based on mathematical frameworks of the Gauss-Newton method and extended Kalman filter, when telemetry and synchronized phasor measurements arrays are used simultaneously. It is confirmed, that the given method increases an accuracy of the voltage and active power flow estimation at steady state and post-accident modes, in contrast tothe standard state estimation method. The developed algorithm enables the implementation of this method into the state estimation block of real time hardware and software systems. The upcoming trends for the development of state estimation methods in the event of dynamic processes in power system areas are also formed
Диспетчерское управление энергосистемами базируется на результатах, полученных из программных комплексов реального времени. Модуль оценивания состояния программных комплексов реального времени является ключевым, так как на основании результатов оценки режимных параметров, полученных из этого модуля, определяются более ёмкие режимные параметры, отвечающие за устойчивость и надёжность работы энергосистем. В настоящее время для оценивания режимных параметров применяются не только телеизмерения, но и синхронизированные векторные измерения, поэтому развитие методов оценивания состояния является актуальной задачей. Предлагаемый метод оценивания состояния позволяет повысить точность оценивания состояния и качество принимаемых диспетчерских решений. Метод базируется на математическом аппарате метода Гаусса-Ньютона и расширенном фильтре Калмана при совместном использовании массивов телеизмерений и синхронизированных векторных измерений. По результатам экспериментов установлено, что по сравнению со стандартным методом оценивания состояния, предлагаемый метод повышает точность оценивания напряжения в узлах схемы и перетоков активной мощности в связях в нормальных и послеаварийных режимах. Разработанный алгоритм позволяет внедрить метод в модуль оценивания состояния программных комплексов реального времени. Определены перспективные направления развития методов оценивания состояния в динамических режимах работы энергосистем
Текстовый файл
Γλώσσα:Αγγλικά
Έκδοση: 2024
Θέματα:
Διαθέσιμο Online:https://doi.org/10.31489/2024No4/61-70
Μορφή: Ηλεκτρονική πηγή Κεφάλαιο βιβλίου
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=678032

MARC

LEADER 00000naa0a2200000 4500
001 678032
005 20250109145212.0
090 |a 678032 
100 |a 20250109d2024 k||y0rusy50 ba 
101 0 |a eng 
102 |a KZ 
135 |a drcn ---uucaa 
181 0 |a i   |b  e  
182 0 |a b 
183 0 |a cr  |2 RDAcarrier 
200 1 |a State estimation of power system mode parameters by telemetry and synchronized phasor measurements  |d Оценивание состояния режимных параметров энергосистем по телеметрии и синхронизированным векторным измерениям  |z rus  |f Batseva N. L., Foos J. A. 
203 |a Текст  |c электронный  |b визуальный 
283 |a online_resource  |2 RDAcarrier 
300 |a Title screen 
320 |a References: 22 tit 
330 |a Real time hardware and software systems are operated at centers of a power system operation. The key unit of these systems is the state estimation block since, based on the results of mode parameters derived from this block, parameters that are more comprehensive can be calculated. These parameters are considered for system stability and reliability. Currently, not only telemetry but also synchronized phasor measurements can be used for a state estimation. Therefore, the development of state estimation methods is the relevant task. The proposed method allows improving the estimation accuracy and the quality of decisions, related to system stability and reliability. The method is based on mathematical frameworks of the Gauss-Newton method and extended Kalman filter, when telemetry and synchronized phasor measurements arrays are used simultaneously. It is confirmed, that the given method increases an accuracy of the voltage and active power flow estimation at steady state and post-accident modes, in contrast tothe standard state estimation method. The developed algorithm enables the implementation of this method into the state estimation block of real time hardware and software systems. The upcoming trends for the development of state estimation methods in the event of dynamic processes in power system areas are also formed 
330 |a Диспетчерское управление энергосистемами базируется на результатах, полученных из программных комплексов реального времени. Модуль оценивания состояния программных комплексов реального времени является ключевым, так как на основании результатов оценки режимных параметров, полученных из этого модуля, определяются более ёмкие режимные параметры, отвечающие за устойчивость и надёжность работы энергосистем. В настоящее время для оценивания режимных параметров применяются не только телеизмерения, но и синхронизированные векторные измерения, поэтому развитие методов оценивания состояния является актуальной задачей. Предлагаемый метод оценивания состояния позволяет повысить точность оценивания состояния и качество принимаемых диспетчерских решений. Метод базируется на математическом аппарате метода Гаусса-Ньютона и расширенном фильтре Калмана при совместном использовании массивов телеизмерений и синхронизированных векторных измерений. По результатам экспериментов установлено, что по сравнению со стандартным методом оценивания состояния, предлагаемый метод повышает точность оценивания напряжения в узлах схемы и перетоков активной мощности в связях в нормальных и послеаварийных режимах. Разработанный алгоритм позволяет внедрить метод в модуль оценивания состояния программных комплексов реального времени. Определены перспективные направления развития методов оценивания состояния в динамических режимах работы энергосистем 
336 |a Текстовый файл 
461 1 |t Eurasian Physical Technical Journal  |c Karaganda  |n KarSU 
463 1 |t Vol. 21, No. 4 (50)  |v P. 61-70  |d 2024 
610 1 |a state estimation 
610 1 |a Gauss-Newton method 
610 1 |a extended Kalman filter 
610 1 |a telemetry 
610 1 |a synchronized phasor measurements 
610 1 |a синтезированный метод оценивания состояния 
610 1 |a метод Гаусса-Ньютона 
610 1 |a расширенный фильтр Калмана 
610 1 |a массивы телеизмерений 
610 1 |a синхронизированные векторные измерения 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
700 1 |a Batseva  |b N. L.  |c Specialist in the field of electric power engineering  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1968-  |g Natalya Lenmirovna  |9 15484 
701 1 |a Foos  |b Yu. A.  |g Yuliya Alekseevna 
712 0 2 |a National Research Tomsk Polytechnic University  |9 27197  |4 570 
801 0 |a RU  |b 63413507  |c 20250109  |g RCR 
856 4 |u https://doi.org/10.31489/2024No4/61-70  |z https://doi.org/10.31489/2024No4/61-70 
942 |c CF