सारांश:Nowadays there is a significant increase the number of generation units based on renewable energy sources in electric power systems, the main goal of which is to ensure global access to affordable, reliable, sustainable and modern sources of energy. However, as the penetration level of renewable generation units increases, there are power oscillations easily occur, which create biggest challenges for the power system stability. In particular, the dominant modes of modern generation units, connected to the main grid via a voltage source converter, are in the range of higher frequencies than electromechanical oscillations. Consequently, the chance of occurrence of low-frequency oscillations increases, the parameters and the trajectory of which will differ from power oscillations in power system without renewables. The results of the analysis of low-frequency oscillation parameters in part of Eastern Siberia power system and evaluation of impact of renewable generation unit on power oscillations are presented in this article. The results were obtained by the Hybrid real time simulator based on the combination of analog, physical and digital modeling levels. The developed scheme of part of Eastern Siberia power system and simulation results were verified by SCADA system. The difference between the results of simulation and SCADA system did not exceed 1%. It indicates the adequacy of the Hybrid real time simulator and the developed scheme of power system. Based on the evaluation of the parameters of power oscillations and the calculation of the degree of damping of the transient process, it can be noted that the oscillatory stability of the power system is improved: damping time decreases, the damping ratio increases with increasing of renewables penetration level.
Текстовый файл
AM_Agreement
भाषा:अंग्रेज़ी
प्रकाशित: 2023
विषय:
ऑनलाइन पहुंच:https://doi.org/10.1016/j.egyr.2023.04.252
स्वरूप: इलेक्ट्रोनिक पुस्तक अध्याय
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=674680

MARC

LEADER 00000naa0a2200000 4500
001 674680
005 20260727161233.0
014 |2 sici 
090 |a 674680 
100 |a 20240918d2023 k||y0rusy50 ca 
101 1 |a eng  |c rus 
102 |a NL 
135 |a drcn ---uucaa 
181 0 |a a   |b  e  
182 0 |a b 
183 0 |a cr  |2 RDAcarrier 
200 1 |a Damping of low-frequency oscillation using renewable generation units  |f Ruslan A. Ufa, Vladimir E. Rudnik, Fujin Deng 
203 |a Текст  |b визуальный  |c электронный 
283 |a online_resource  |2 RDAcarrier 
320 |a References : 27 tit. 
330 |a Nowadays there is a significant increase the number of generation units based on renewable energy sources in electric power systems, the main goal of which is to ensure global access to affordable, reliable, sustainable and modern sources of energy. However, as the penetration level of renewable generation units increases, there are power oscillations easily occur, which create biggest challenges for the power system stability. In particular, the dominant modes of modern generation units, connected to the main grid via a voltage source converter, are in the range of higher frequencies than electromechanical oscillations. Consequently, the chance of occurrence of low-frequency oscillations increases, the parameters and the trajectory of which will differ from power oscillations in power system without renewables. The results of the analysis of low-frequency oscillation parameters in part of Eastern Siberia power system and evaluation of impact of renewable generation unit on power oscillations are presented in this article. The results were obtained by the Hybrid real time simulator based on the combination of analog, physical and digital modeling levels. The developed scheme of part of Eastern Siberia power system and simulation results were verified by SCADA system. The difference between the results of simulation and SCADA system did not exceed 1%. It indicates the adequacy of the Hybrid real time simulator and the developed scheme of power system. Based on the evaluation of the parameters of power oscillations and the calculation of the degree of damping of the transient process, it can be noted that the oscillatory stability of the power system is improved: damping time decreases, the damping ratio increases with increasing of renewables penetration level. 
336 |a Текстовый файл 
371 0 |a AM_Agreement 
461 1 |t Energy Reports  |c Amsterdam  |n Elsevier Science Publishing Company Inc. 
463 1 |t Vol. 9, supp. 8 : The 3rd International Conference on Power Engineering (ICPE 2022)  |v P. 25-31  |d 2023  |o Science and Engineering Institute, China Chapter, December 09–11, 2022, Sanya, Hainan Province, China 
610 1 |a Renewable energy sources 
610 1 |a Low-frequency oscillations 
610 1 |a Oscillatory stability 
610 1 |a Simulation 
610 1 |a труды учёных ТПУ 
610 1 |a электронный ресурс 
700 1 |a Ufa  |b R. A.  |c specialist in the field of electric power engineering  |c Associate Professor of Tomsk Polytechnic University, Candidate of Technical Sciences  |f 1988-  |g Ruslan Alexandrovich  |9 16731 
701 1 |a Rudnik  |b V. E.  |c Specialist in the field of electric power engineering  |c Research Engineer of Tomsk Polytechnic University  |f 1995-  |g Vladimir Evgenevich  |9 21532 
701 1 |a Deng  |b F.  |g Fujin 
712 0 2 |a Томский политехнический университет  |c 1991-  |9 26305  |4 570 
801 0 |a RU  |b 63413507  |c 20240918 
850 |a 63413507 
856 4 |u https://doi.org/10.1016/j.egyr.2023.04.252  |z https://doi.org/10.1016/j.egyr.2023.04.252 
942 |c CR