Increasing the Efficiency of Diagnostics in the Brush-Commutator Assembly of a Direct Current Electric Motor; Energies; Vol. 17, iss. 1

Bibliografiske detaljer
Parent link:Energies.— .— Basel: MDPI AG
Vol. 17, iss. 1.— 2024.— Article number 17, 24 p.
Institution som forfatter: National Research Tomsk Polytechnic University
Andre forfattere: Filina O. A. Olga Alekseevna, Martyushev N. V. Nikita Vladimirovich, Malozemov B. V. Boris Vitaljevich, Tynchenko V. S. Vadim Sergeevich, Kukartsev V. A. Viktor Alekseevich, Bashmur K. A. Kirill Aleksandrovich, Pavlov P. P. Pavel Pavlovich, Panfilova T. A. Tatjyana Aleksandrovna
Summary:Title screen
Increasing the productivity and reliability of mining infrastructure facilities is an important task in achieving future goals. Mining dump trucks are an important part of coal mine infrastructure. In this article, to determine the reliability indicators in a brush–commutator unit and the residual life of electric motor brushes, a mathematical model for processing statistical data has been developed, which allows for the classification of types of failures and, unlike existing models, the determination of the life of the brushes according to the maximum extent of their wear. A method for predicting the residual life of an electric brush in a DC electric motor is presented, which contains a list of controlled reliability indicators, included a mathematical model. The described model improves the accuracy of the prediction and detection of DC motor failures. The derivation of the general formula for calculating the residual life of electric brushes is given. Based on the proposed mathematical model, we studied and calculated the reliability of the brush–commutator unit, the minimum height of the brush during operation, the average rate of its wear, the standard deviation and the mathematical expectation of brush wear. A nomogram of the failure-free operation time of the brush–commutator unit in a DC electric motor was modeled using the height of the brush during operation. Output parameters after the implementation of this monitoring system include the reliability of the electric motor operation. At the same time, diagnostic characteristics are improved twofold, and the residual life of the brush-switching unit is increased by 28–30%
Текстовый файл
Sprog:engelsk
Udgivet: 2024
Fag:
Online adgang:http://earchive.tpu.ru/handle/11683/132501
https://doi.org/10.3390/en17010017
Format: Electronisk Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=672790

MARC

LEADER 00000naa0a2200000 4500
001 672790
005 20250915103544.0
090 |a 672790 
100 |a 20240528d2024 k||y0rusy50 ba 
101 0 |a eng 
102 |a CH 
135 |a drcn ---uucaa 
181 0 |a i   |b  e  
182 0 |a b 
183 0 |a cr  |2 RDAcarrier 
200 1 |a Increasing the Efficiency of Diagnostics in the Brush-Commutator Assembly of a Direct Current Electric Motor  |f O. A. Filina, N. V. Martyushev, B. V. Malozemov [et al.] 
203 |a Текст  |b визуальный  |c электронный 
283 |a online_resource  |2 RDAcarrier 
300 |a Title screen 
320 |a References: 51 tit 
330 |a Increasing the productivity and reliability of mining infrastructure facilities is an important task in achieving future goals. Mining dump trucks are an important part of coal mine infrastructure. In this article, to determine the reliability indicators in a brush–commutator unit and the residual life of electric motor brushes, a mathematical model for processing statistical data has been developed, which allows for the classification of types of failures and, unlike existing models, the determination of the life of the brushes according to the maximum extent of their wear. A method for predicting the residual life of an electric brush in a DC electric motor is presented, which contains a list of controlled reliability indicators, included a mathematical model. The described model improves the accuracy of the prediction and detection of DC motor failures. The derivation of the general formula for calculating the residual life of electric brushes is given. Based on the proposed mathematical model, we studied and calculated the reliability of the brush–commutator unit, the minimum height of the brush during operation, the average rate of its wear, the standard deviation and the mathematical expectation of brush wear. A nomogram of the failure-free operation time of the brush–commutator unit in a DC electric motor was modeled using the height of the brush during operation. Output parameters after the implementation of this monitoring system include the reliability of the electric motor operation. At the same time, diagnostic characteristics are improved twofold, and the residual life of the brush-switching unit is increased by 28–30% 
336 |a Текстовый файл 
461 1 |t Energies  |c Basel  |n MDPI AG 
463 1 |t Vol. 17, iss. 1  |v Article number 17, 24 p.  |d 2024 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a DC electric motor 
610 1 |a brush wear 
610 1 |a diagnosing 
610 1 |a commutation stability 
610 1 |a operating modes 
610 1 |a mining dump truck 
701 1 |a Filina  |b O. A.   |g Olga Alekseevna 
701 1 |a Martyushev  |b N. V.  |c specialist in the field of material science  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1981-  |g Nikita Vladimirovich  |9 16754 
701 1 |a Malozemov  |b B. V.  |g Boris Vitaljevich 
701 1 |a Tynchenko  |b V. S.  |g Vadim Sergeevich 
701 1 |a Kukartsev  |b V. A.  |g Viktor Alekseevich 
701 1 |a Bashmur  |b K. A.  |g Kirill Aleksandrovich 
701 1 |a Pavlov  |b P. P.  |g Pavel Pavlovich 
701 1 |a Panfilova  |b T. A.  |g Tatjyana Aleksandrovna 
712 0 2 |a National Research Tomsk Polytechnic University  |c (2009- )  |9 27197 
801 0 |a RU  |b 63413507  |c 20240528 
850 |a 63413507 
856 4 |u http://earchive.tpu.ru/handle/11683/132501  |z http://earchive.tpu.ru/handle/11683/132501 
856 4 |u https://doi.org/10.3390/en17010017  |z https://doi.org/10.3390/en17010017 
942 |c CR