Analysis of low-frequency oscillation in power system with renewable energy sources; Energy Reports; Vol. 8

Podrobná bibliografie
Parent link:Energy Reports
Vol. 8.— 2022.— [P. 394-405]
Další autoři: Rudnik V. E. Vladimir Evgenevich, Ufa R. A. Ruslan Alexandrovich, Malkova Ya. Yu. Yana Yurievna
Shrnutí:Title screen
The development of electric power systems determines the growing probability of low-frequency oscillations, which can be reason of system faults. Traditionally, the task of damping low-frequency oscillations is assigned to synchronous generators, by appropriate setting of the automatic voltage regulator parameters. However, as the installed capacity of renewable generation units increases, research aimed to analyse the impact of these generation units on the power oscillations in the electric power system is becoming more relevant. Moreover, an evaluation of the potential of renewables to solve the problems of power oscillation damping seems necessary to expand the operation functions of the these generation units and to increase the stability of the electric power systems. This paper presents an analysis of renewable energy plants, in particular photovoltaic stations, on damping of these power oscillations. Achieving such damping function is possible via upgrading the automatic control system of photovoltaic stations by using a synthetic inertia block and the possibilities of the “underload” mode. Different scenarios, including small disturbances and severe fault condition for strong and weak grids depending on the location and capacity of photovoltaic station were considered. To evaluate the impact of renewable generation unit to the damping properties of electric power system, the transient damping ratio was calculated. The calculation was carried out in accordance with the guidelines in case of three-phase short-circuit for a different penetration level of renewable generation unit, as well as with and without the synthetic inertia block.
Режим доступа: по договору с организацией-держателем ресурса
Jazyk:angličtina
Vydáno: 2022
Témata:
On-line přístup:https://doi.org/10.1016/j.egyr.2022.07.022
Médium: MixedMaterials Elektronický zdroj Kapitola
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=668550

MARC

LEADER 00000naa0a2200000 4500
001 668550
005 20251203110719.0
035 |a (RuTPU)RU\TPU\network\39777 
035 |a RU\TPU\network\39210 
090 |a 668550 
100 |a 20221227d2022 k||y0rusy50 ba 
101 0 |a eng 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Analysis of low-frequency oscillation in power system with renewable energy sources  |f V. E. Rudnik, R. A. Ufa, Ya. Yu. Malkova 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 39 tit.] 
330 |a The development of electric power systems determines the growing probability of low-frequency oscillations, which can be reason of system faults. Traditionally, the task of damping low-frequency oscillations is assigned to synchronous generators, by appropriate setting of the automatic voltage regulator parameters. However, as the installed capacity of renewable generation units increases, research aimed to analyse the impact of these generation units on the power oscillations in the electric power system is becoming more relevant. Moreover, an evaluation of the potential of renewables to solve the problems of power oscillation damping seems necessary to expand the operation functions of the these generation units and to increase the stability of the electric power systems. This paper presents an analysis of renewable energy plants, in particular photovoltaic stations, on damping of these power oscillations. Achieving such damping function is possible via upgrading the automatic control system of photovoltaic stations by using a synthetic inertia block and the possibilities of the “underload” mode. Different scenarios, including small disturbances and severe fault condition for strong and weak grids depending on the location and capacity of photovoltaic station were considered. To evaluate the impact of renewable generation unit to the damping properties of electric power system, the transient damping ratio was calculated. The calculation was carried out in accordance with the guidelines in case of three-phase short-circuit for a different penetration level of renewable generation unit, as well as with and without the synthetic inertia block. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Energy Reports 
463 |t Vol. 8  |v [P. 394-405]  |d 2022 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a electric power system 
610 1 |a low frequency oscillation 
610 1 |a damping 
610 1 |a renewable energy sources 
610 1 |a transient damping ratio 
610 1 |a synthetic inertia 
701 1 |a Rudnik  |b V. E.  |c Specialist in the field of electric power engineering  |c Research Engineer of Tomsk Polytechnic University  |f 1995-  |g Vladimir Evgenevich  |3 (RuTPU)RU\TPU\pers\42419  |9 21532 
701 1 |a Ufa  |b R. A.  |c specialist in the field of electric power engineering  |c Associate Professor of Tomsk Polytechnic University, Candidate of Technical Sciences  |f 1988-  |g Ruslan Alexandrovich  |3 (RuTPU)RU\TPU\pers\32883  |9 16731 
701 1 |a Malkova  |b Ya. Yu.  |c specialist in the field of electric power engineering  |c Assistant of assistant of the department Tomsk Polytechnic University  |f 1996-  |g Yana Yurievna  |y Tomsk  |3 (RuTPU)RU\TPU\pers\47209  |9 22789 
801 0 |a RU  |b 63413507  |c 20221227  |g RCR 
856 4 |u https://doi.org/10.1016/j.egyr.2022.07.022 
942 |c CF