Influence of Vertical Rib Size on UF6 Desublimation in Vertical Submersible Tanks

Detalhes bibliográficos
Parent link:Atomic Energy
Vol. 131, iss. 1.— 2021.— [P. 37-41]
Autor principal: Orlov A. A. Aleksey Alekseevich
Autor Corporativo: Национальный исследовательский Томский политехнический университет Инженерная школа ядерных технологий Отделение ядерно-топливного цикла
Outros Autores: Verlinsky M. V. Maksim Vadimovich, Malyugin R. V. Roman Vladislavovich
Resumo:Title screen
The predictables of non-stationary desublimation of UF6 in vertical submersible tanks with vertical ribbing were investigated by means of numerical modeling using a simplified three-dimensional mathematical model. The computational results for the average capacity of tanks with vertical ribbing with volume 1–4 m3 are given as a function of the width and length of the vertical. It is shown that the average capacity of tanks with vertical ribbing can be increased by changing the width and length of the ribs.
Режим доступа: по договору с организацией-держателем ресурса
Idioma:inglês
Publicado em: 2021
Assuntos:
Acesso em linha:https://doi.org/10.1007/s10512-022-00833-z
Formato: Recurso Electrónico Capítulo de Livro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=668488

Registos relacionados