Influence of Vertical Rib Size on UF6 Desublimation in Vertical Submersible Tanks

Bibliographic Details
Parent link:Atomic Energy
Vol. 131, iss. 1.— 2021.— [P. 37-41]
Main Author: Orlov A. A. Aleksey Alekseevich
Corporate Author: Национальный исследовательский Томский политехнический университет Инженерная школа ядерных технологий Отделение ядерно-топливного цикла
Other Authors: Verlinsky M. V. Maksim Vadimovich, Malyugin R. V. Roman Vladislavovich
Summary:Title screen
The predictables of non-stationary desublimation of UF6 in vertical submersible tanks with vertical ribbing were investigated by means of numerical modeling using a simplified three-dimensional mathematical model. The computational results for the average capacity of tanks with vertical ribbing with volume 1–4 m3 are given as a function of the width and length of the vertical. It is shown that the average capacity of tanks with vertical ribbing can be increased by changing the width and length of the ribs.
Режим доступа: по договору с организацией-держателем ресурса
Language:English
Published: 2021
Subjects:
Online Access:https://doi.org/10.1007/s10512-022-00833-z
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=668488

MARC

LEADER 00000naa0a2200000 4500
001 668488
005 20250624092232.0
035 |a (RuTPU)RU\TPU\network\39715 
035 |a RU\TPU\network\39325 
090 |a 668488 
100 |a 20221214d2021 k||y0rusy50 ba 
101 1 |a eng 
102 |a US 
135 |a drgn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Influence of Vertical Rib Size on UF6 Desublimation in Vertical Submersible Tanks  |f A. A. Orlov, M. V. Verlinsky, R. V. Malyugin 
203 |a Текст  |c электронный 
300 |a Title screen 
320 |a [References: 6 tit.] 
330 |a The predictables of non-stationary desublimation of UF6 in vertical submersible tanks with vertical ribbing were investigated by means of numerical modeling using a simplified three-dimensional mathematical model. The computational results for the average capacity of tanks with vertical ribbing with volume 1–4 m3 are given as a function of the width and length of the vertical. It is shown that the average capacity of tanks with vertical ribbing can be increased by changing the width and length of the ribs. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Atomic Energy 
463 |t Vol. 131, iss. 1  |v [P. 37-41]  |d 2021 
610 1 |a труды учёных ТПУ 
610 1 |a электронный ресурс 
610 1 |a численное моделирование 
610 1 |a математическая модель 
610 1 |a десублимация 
610 1 |a резервуары 
700 1 |a Orlov  |b A. A.  |c physicist  |c Professor of Tomsk Polytechnic University, Doctor of technical sciences  |f 1962-  |g Aleksey Alekseevich  |3 (RuTPU)RU\TPU\pers\34230  |9 17761 
701 1 |a Verlinsky  |b M. V.  |g Maksim Vadimovich 
701 1 |a Malyugin  |b R. V.  |g Roman Vladislavovich 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа ядерных технологий  |b Отделение ядерно-топливного цикла  |3 (RuTPU)RU\TPU\col\23554 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа ядерных технологий  |b Отделение ядерно-топливного цикла  |3 (RuTPU)RU\TPU\col\23554 
801 2 |a RU  |b 63413507  |c 20221214  |g RCR 
850 |a 63413507 
856 4 |u https://doi.org/10.1007/s10512-022-00833-z  |z https://doi.org/10.1007/s10512-022-00833-z 
942 |c CF