Structuring of reference data on the hygroscopic points of soluble substances in the range 41–69% RH

التفاصيل البيبلوغرافية
Parent link:Journal of Chemical Thermodynamics
Vol. 171.— 2022.— [106790, 5 p.]
المؤلف الرئيسي: Tereshchenko A. G. Anatoly Georgievich
مؤلف مشترك: Национальный исследовательский Томский политехнический университет Инженерная школа новых производственных технологий Научно-производственная лаборатория "Чистая вода"
الملخص:Title screen
The dynamic method has been used to determine hygroscopic points of a series of substances in the range of 41 - 69 % RH, which is characterized by a transition from optimal to non-recommended relative air humidity. The hygroscopic points are presented as a decreasing series; their values are mutually consistent with each other; the standard uncertainty of hygroscopic points is 0.3-0.6% RH. The investigated substances are recommended to expand the number of reference substances given in ASTM E 104-02, saturated solutions of which can be used to set relative air humidity in laboratory practice. It is noted that some substances, including those listed in ASTM E 104-02, should be used with caution when studying hygroscopic processes since they (their solutions) release into the gas phase not solely water vapor but also other substances that can distort the hygroscopic process run with the participation of these substances.
Режим доступа: по договору с организацией-держателем ресурса
اللغة:الإنجليزية
منشور في: 2022
الموضوعات:
الوصول للمادة أونلاين:https://doi.org/10.1016/j.jct.2022.106790
التنسيق: الكتروني فصل الكتاب
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=668025
الوصف
الملخص:Title screen
The dynamic method has been used to determine hygroscopic points of a series of substances in the range of 41 - 69 % RH, which is characterized by a transition from optimal to non-recommended relative air humidity. The hygroscopic points are presented as a decreasing series; their values are mutually consistent with each other; the standard uncertainty of hygroscopic points is 0.3-0.6% RH. The investigated substances are recommended to expand the number of reference substances given in ASTM E 104-02, saturated solutions of which can be used to set relative air humidity in laboratory practice. It is noted that some substances, including those listed in ASTM E 104-02, should be used with caution when studying hygroscopic processes since they (their solutions) release into the gas phase not solely water vapor but also other substances that can distort the hygroscopic process run with the participation of these substances.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.1016/j.jct.2022.106790