Application of Software Systems for Calculating Permissible Active Power Flows in Real Time; AIP Conference Proceedings; Vol. 2422 : Heat and mass transfer in the thermal control system of technical and technological energy equipment (HMTTSC 2021)

Dettagli Bibliografici
Parent link:AIP Conference Proceedings
Vol. 2422 : Heat and mass transfer in the thermal control system of technical and technological energy equipment (HMTTSC 2021).— 2021.— [020009, 2 p.]
Autore principale: Tomalev A. A. Andrei
Ente Autore: Национальный исследовательский Томский политехнический университет Инженерная школа энергетики Отделение электроэнергетики и электротехники
Altri autori: Andreev M. V. Mikhail Vladimirovich
Riassunto:Title screen
The expedience of using digital technologies in the control of power modes, in particular, software systems which use actual telemetric information it is opportunities for more high transmission throughput. The software systems what we have in nowadays use for calculating of power flow in transmission actual telemetric information and information which was made by a researcher: vector of power mode change, list of disturbances in power system, algorithm of emergency automation. This paper present results of using that software on the example of the transmission voltage class 220 kV and 500 kV.
Lingua:inglese
Pubblicazione: 2021
Serie:Thermosyphons, evaporation and condensation in porous and disperse media, system of local evaporative cooling
Soggetti:
Accesso online:https://doi.org/10.1063/5.0068299
Natura: Elettronico Capitolo di libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=667480

MARC

LEADER 00000naa2a2200000 4500
001 667480
005 20251117144634.0
035 |a (RuTPU)RU\TPU\network\38685 
035 |a RU\TPU\network\38649 
090 |a 667480 
100 |a 20220329d2021 k||y0rusy50 ba 
101 0 |a eng 
135 |a drgn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Application of Software Systems for Calculating Permissible Active Power Flows in Real Time  |f A. A. Tomalev, M. V. Andreev 
203 |a Text  |c electronic 
225 1 |a Thermosyphons, evaporation and condensation in porous and disperse media, system of local evaporative cooling 
300 |a Title screen 
320 |a [References: 3 tit.] 
330 |a The expedience of using digital technologies in the control of power modes, in particular, software systems which use actual telemetric information it is opportunities for more high transmission throughput. The software systems what we have in nowadays use for calculating of power flow in transmission actual telemetric information and information which was made by a researcher: vector of power mode change, list of disturbances in power system, algorithm of emergency automation. This paper present results of using that software on the example of the transmission voltage class 220 kV and 500 kV. 
461 0 |0 (RuTPU)RU\TPU\network\4816  |t AIP Conference Proceedings 
463 0 |0 (RuTPU)RU\TPU\network\38674  |t Vol. 2422 : Heat and mass transfer in the thermal control system of technical and technological energy equipment (HMTTSC 2021)  |o International Youth Scientific Conference, 20–22 April 2021, Tomsk, Russia  |f National Research Tomsk Polytechnic University (TPU) ; eds. G. V. Kuznetsov, D. V. Feoktistov, E. G. Orlova  |v [020009, 2 p.]  |d 2021 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a программные комплексы 
610 1 |a перетоки 
610 1 |a режимы реального времени 
610 1 |a цифровые технологии 
610 1 |a режимы 
610 1 |a мощность 
610 1 |a пропускные способности 
700 1 |a Tomalev  |b A. A.  |g Andrei 
701 1 |a Andreev  |b M. V.  |c specialist in the field of electric power engineering  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1987-  |g Mikhail Vladimirovich  |3 (RuTPU)RU\TPU\pers\35035 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа энергетики  |b Отделение электроэнергетики и электротехники  |3 (RuTPU)RU\TPU\col\23505 
801 2 |a RU  |b 63413507  |c 20220329  |g RCR 
856 4 |u https://doi.org/10.1063/5.0068299 