A Hardware and Software System for Point-of-Care Testing of the Functional State of the Hemostasis System; Biomedical Engineering; Vol. 55, iss. 3
| Parent link: | Biomedical Engineering Vol. 55, iss. 3.— 2021.— [P. 164–168] |
|---|---|
| Glavni avtor: | |
| Korporativna značnica: | |
| Drugi avtorji: | , |
| Izvleček: | Title screen A hardware and software system for point-of-care (bedside) testing of the functional state of the hemostasis system using the patient’s native blood has been developed. The block diagram of the system is presented and the main hardware and software solutions are described. A piezotransducer for low-frequency piezotromboelasto-graphy has been designed. The developed hardware and software system has been used for real-time monitoring of vascular platelet hemostasis in volunteers. The test has demonstrated a high degree of compliance with the standard methods for assessing the functional state of the hemostasis system. An advantage of the system is that it provides point-of-care testing of whole blood. Режим доступа: по договору с организацией-держателем ресурса |
| Jezik: | angleščina |
| Izdano: |
2021
|
| Teme: | |
| Online dostop: | https://doi.org/10.1007/s10527-021-10094-y |
| Format: | Elektronski Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=666361 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 666361 | ||
| 005 | 20250214170157.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\37565 | ||
| 035 | |a RU\TPU\network\34956 | ||
| 090 | |a 666361 | ||
| 100 | |a 20211217d2021 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a US | ||
| 135 | |a drgn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a A Hardware and Software System for Point-of-Care Testing of the Functional State of the Hemostasis System |f D. S. Slizevich, F. A. Gubarev, I. I. Tyutrin | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 8 tit.] | ||
| 330 | |a A hardware and software system for point-of-care (bedside) testing of the functional state of the hemostasis system using the patient’s native blood has been developed. The block diagram of the system is presented and the main hardware and software solutions are described. A piezotransducer for low-frequency piezotromboelasto-graphy has been designed. The developed hardware and software system has been used for real-time monitoring of vascular platelet hemostasis in volunteers. The test has demonstrated a high degree of compliance with the standard methods for assessing the functional state of the hemostasis system. An advantage of the system is that it provides point-of-care testing of whole blood. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Biomedical Engineering | ||
| 463 | |t Vol. 55, iss. 3 |v [P. 164–168] |d 2021 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a аппаратно-программные комплексы | |
| 610 | 1 | |a тестирование | |
| 610 | 1 | |a гемостаз | |
| 610 | 1 | |a пьезотромбоэластография | |
| 610 | 1 | |a тромбоциты | |
| 610 | 1 | |a медицинская помощь | |
| 700 | 1 | |a Slizevich |b D. S. |g Dmitry Sergeevich | |
| 701 | 1 | |a Gubarev |b F. A. |c specialist in the field of electronics |c Associate Professor of Tomsk Polytechnic University, Candidate of physical and mathematical sciences |f 1979- |g Fedor Aleksandrovich |3 (RuTPU)RU\TPU\pers\31657 |9 15794 | |
| 701 | 1 | |a Tyutrin |b I. I. |g Ivan Illarionovich | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Исследовательская школа химических и биомедицинских технологий |c (2017- ) |3 (RuTPU)RU\TPU\col\23537 |
| 801 | 2 | |a RU |b 63413507 |c 20211217 |g RCR | |
| 856 | 4 | |u https://doi.org/10.1007/s10527-021-10094-y | |
| 942 | |c CF | ||