The dependency of fast neutron flux and spectra on the collimation-field size and geometry for fast neutron therapy purposes; Radiation Effects and Defects in Solids; Vol. 176, iss. 9-10

书目详细资料
Parent link:Radiation Effects and Defects in Solids
Vol. 176, iss. 9-10.— 2021.— [P. 777-788]
主要作者: Shehada A. Abdullah
企业作者: Национальный исследовательский Томский политехнический университет Инженерная школа ядерных технологий Научно-образовательный центр Б. П. Вейнберга
其他作者: Krivobokov V. P. Valery Pavlovich
总结:Title screen
The aim of this work is to optimize and investigate the relationship between the collimation-filed size and their geometries and the fast-neutron intensity and their energy-spectrum. Advantageously for these purposes, a prototype of collimator was designed and constructed to simulate different geometrical and materials compositions. Beams of fast neutrons generated by the reaction 9Be(d, n) with 13.6 MeV deuteron energy were investigated. The average energy of the emitted neutrons is about 6-7 MeV. The maximum intensity was at neutron energy of 4-5 MeV. In the process of the study, experimental works were carried out with Al, Fe, Cu and Cd foils which positioned on the collimator aperture as neutron detectors. The neutron activation method and Gamma-spectrometer were deployed to determine the neutron intensities within the energy-range from thermal energies to 14 MeV. Experiments were conducted for ten different combinations of materials and geometries which can be adjusted by the removable-polyethylene collimator parts and the metal parts. It was concluded that the thermal and fast neutron flux were depended on the collimation-field size and materials, where the fast neutron flux output was about 100% more for bigger collimator 9•9 cm2 comparing with the smaller ones 5•5 cm2 . And more than 60% in case of adding Lead layers into the collimator. These results could have influential implications on the fast neutron intensities and improvement of collimation systems for fast neutron therapy. Also, it could enhance the irradiation fluxes in the irradiation channels in nuclear reactors for medical isotopes productions and material testing and other applications.
Режим доступа: по договору с организацией-держателем ресурса
语言:英语
出版: 2021
主题:
在线阅读:https://doi.org/10.1080/10420150.2021.1954001
格式: 电子 本书章节
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=666226

MARC

LEADER 00000naa0a2200000 4500
001 666226
005 20250213172243.0
035 |a (RuTPU)RU\TPU\network\37430 
035 |a RU\TPU\network\36516 
090 |a 666226 
100 |a 20211210d2021 k||y0rusy50 ba 
101 0 |a eng 
102 |a GB 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a The dependency of fast neutron flux and spectra on the collimation-field size and geometry for fast neutron therapy purposes  |f A. Shehada, V. P. Krivobokov 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 24 tit.] 
330 |a The aim of this work is to optimize and investigate the relationship between the collimation-filed size and their geometries and the fast-neutron intensity and their energy-spectrum. Advantageously for these purposes, a prototype of collimator was designed and constructed to simulate different geometrical and materials compositions. Beams of fast neutrons generated by the reaction 9Be(d, n) with 13.6 MeV deuteron energy were investigated. The average energy of the emitted neutrons is about 6-7 MeV. The maximum intensity was at neutron energy of 4-5 MeV. In the process of the study, experimental works were carried out with Al, Fe, Cu and Cd foils which positioned on the collimator aperture as neutron detectors. The neutron activation method and Gamma-spectrometer were deployed to determine the neutron intensities within the energy-range from thermal energies to 14 MeV. Experiments were conducted for ten different combinations of materials and geometries which can be adjusted by the removable-polyethylene collimator parts and the metal parts. It was concluded that the thermal and fast neutron flux were depended on the collimation-field size and materials, where the fast neutron flux output was about 100% more for bigger collimator 9•9 cm2 comparing with the smaller ones 5•5 cm2 . And more than 60% in case of adding Lead layers into the collimator. These results could have influential implications on the fast neutron intensities and improvement of collimation systems for fast neutron therapy. Also, it could enhance the irradiation fluxes in the irradiation channels in nuclear reactors for medical isotopes productions and material testing and other applications. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Radiation Effects and Defects in Solids 
463 |t Vol. 176, iss. 9-10  |v [P. 777-788]  |d 2021 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a fast neutron therapy 
610 1 |a cyclotron 
610 1 |a neutron spectrum 
610 1 |a dose rate 
610 1 |a терапия 
610 1 |a быстрые нейтроны 
610 1 |a циклотроны 
610 1 |a спектры 
610 1 |a мощность 
610 1 |a дозы облучения 
610 1 |a коллиматоры 
700 1 |a Shehada  |b A.  |g Abdullah 
701 1 |a Krivobokov  |b V. P.  |c Russian physicist  |c professor of Tomsk Polytechnic University (TPU), Doctor of Physical and Mathematical Sciences (DSc)  |f 1948-  |g Valery Pavlovich  |3 (RuTPU)RU\TPU\pers\30416  |9 14757 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа ядерных технологий  |b Научно-образовательный центр Б. П. Вейнберга  |3 (RuTPU)RU\TPU\col\23561 
801 2 |a RU  |b 63413507  |c 20211210  |g RCR 
856 4 |u https://doi.org/10.1080/10420150.2021.1954001 
942 |c CF