Determination of the Size of the Focal Spot of Betatron Bremsstrahlung Using Collimators; Instruments and Experimental Techniques; Vol. 64, iss. 3
| Parent link: | Instruments and Experimental Techniques Vol. 64, iss. 3.— 2021.— [P. 483-490] |
|---|---|
| 1. Verfasser: | |
| Körperschaft: | |
| Weitere Verfasser: | |
| Zusammenfassung: | Title screen The results of testing a method for measuring the focal spot of bremsstrahlung using a “special lead lens” are presented. The test was performed on the basis of experimental dose distributions in the detector that were obtained during studies of the characteristics of bremsstrahlung radiation of a betatron at an acceleration energy of 4 MeV. The method was modeled using a set of collimators with different sizes of cylindrical apertures. It is shown that in comparison with slit collimators, the use of collimators with cylindrical apertures, including a “special lead lens,” leads to interdependence of the measurement results in different directions. Режим доступа: по договору с организацией-держателем ресурса |
| Sprache: | Englisch |
| Veröffentlicht: |
2021
|
| Schlagworte: | |
| Online-Zugang: | https://doi.org/10.1134/S0020441221020184 |
| Format: | Elektronisch Buchkapitel |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=665991 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 665991 | ||
| 005 | 20250211165310.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\37195 | ||
| 035 | |a RU\TPU\network\35814 | ||
| 090 | |a 665991 | ||
| 100 | |a 20211126d2021 k||y0rusy50 ba | ||
| 101 | 1 | |a eng | |
| 102 | |a US | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Determination of the Size of the Focal Spot of Betatron Bremsstrahlung Using Collimators |f V. B. Sorokin, E. L. Malikov | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 7 tit.] | ||
| 330 | |a The results of testing a method for measuring the focal spot of bremsstrahlung using a “special lead lens” are presented. The test was performed on the basis of experimental dose distributions in the detector that were obtained during studies of the characteristics of bremsstrahlung radiation of a betatron at an acceleration energy of 4 MeV. The method was modeled using a set of collimators with different sizes of cylindrical apertures. It is shown that in comparison with slit collimators, the use of collimators with cylindrical apertures, including a “special lead lens,” leads to interdependence of the measurement results in different directions. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Instruments and Experimental Techniques | ||
| 463 | |t Vol. 64, iss. 3 |v [P. 483-490] |d 2021 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a тормозное излучение | |
| 610 | 1 | |a исследования | |
| 700 | 1 | |a Sorokin |b V. B. |c Physicist |c Senior researcher of Tomsk Polytechnic University |f 1946- |g Vladimir Borisovich |3 (RuTPU)RU\TPU\pers\34819 | |
| 701 | 1 | |a Malikov |b E. L. |c physicist |c Researcher of Tomsk Polytechnic University |f 1978- |g Evgeny Lvovich (L'vovich) |3 (RuTPU)RU\TPU\pers\32863 |9 16711 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Инженерная школа неразрушающего контроля и безопасности |b Центр промышленной томографии |b Научно-производственная лаборатория "Бетатронная томография крупногабаритных объектов" |3 (RuTPU)RU\TPU\col\23717 |
| 801 | 2 | |a RU |b 63413507 |c 20211220 |g RCR | |
| 856 | 4 | |u https://doi.org/10.1134/S0020441221020184 | |
| 942 | |c CF | ||