Determination of Inactive Powers in a Single-Phase AC Network; Energies; Vol. 14, iss. 16

Podrobná bibliografie
Parent link:Energies
Vol. 14, iss. 16.— 2021.— [4814, 13 p.]
Korporativní autor: Национальный исследовательский Томский политехнический университет Инженерная школа новых производственных технологий Отделение материаловедения
Další autoři: Shchurov N. I. Nikolay Ivanovich, Myatezh S. V. Sergey Vladimirovich, Malozemov B. V. Boris Vitaljevich, Shtang A. A. Aleksandr Aleksandrovich, Martyushev N. V. Nikita Vladimirovich, Klyuev R. V. Roman Vladimirovich, Dedov S. I. Sergey Igorevich
Shrnutí:Title screen
Based on the development of the theory of reactive power and distortion power, starting with the works of Fryze and Budeanu, it has been found that the contradictions in the definition of the components of inactive powers are caused by errors in the introduced intermediate concepts and corresponding calculations when switching to nonlinear and non-sinusoidal AC circuits. The materials of the works of modern researchers and the numerical calculations carried out made it possible to trace the differences between reactive power and distortion power, to confirm the orthogonality properties of the active, reactive power, and distortion power components. The paper defines the conditions for achieving a power balance in an AC network with nonlinear loads, compiled and tested criteria leading to the absence of distortion power in a single-phase AC network. Using the time base of the projection of the generalized vectors in vector diagrams, it is shown that compliance with the criteria for the absence of distortion power does not determine the mutual similarity of the voltage curve with the current curve for a nonlinear load. It has been found that the well-known term “distortion power” has an unfortunate wording, since this power, although it characterizes the interaction of harmonics of currents and voltages with different ordinal numbers, is not determined by the visual similarity or the degree of distortion of the load current waveforms relative to the supply voltage curve.
Jazyk:angličtina
Vydáno: 2021
Témata:
On-line přístup:http://earchive.tpu.ru/handle/11683/68963
https://doi.org/10.3390/en14164814
Médium: Elektronický zdroj Kapitola
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=665773

MARC

LEADER 00000naa0a2200000 4500
001 665773
005 20250204165716.0
035 |a (RuTPU)RU\TPU\network\36977 
035 |a RU\TPU\network\35796 
090 |a 665773 
100 |a 20211115d2021 k||y0rusy50 ba 
101 0 |a eng 
102 |a CH 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Determination of Inactive Powers in a Single-Phase AC Network  |f N. I. Shchurov, S. V. Myatezh, B. V. Malozemov [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 33 tit.] 
330 |a Based on the development of the theory of reactive power and distortion power, starting with the works of Fryze and Budeanu, it has been found that the contradictions in the definition of the components of inactive powers are caused by errors in the introduced intermediate concepts and corresponding calculations when switching to nonlinear and non-sinusoidal AC circuits. The materials of the works of modern researchers and the numerical calculations carried out made it possible to trace the differences between reactive power and distortion power, to confirm the orthogonality properties of the active, reactive power, and distortion power components. The paper defines the conditions for achieving a power balance in an AC network with nonlinear loads, compiled and tested criteria leading to the absence of distortion power in a single-phase AC network. Using the time base of the projection of the generalized vectors in vector diagrams, it is shown that compliance with the criteria for the absence of distortion power does not determine the mutual similarity of the voltage curve with the current curve for a nonlinear load. It has been found that the well-known term “distortion power” has an unfortunate wording, since this power, although it characterizes the interaction of harmonics of currents and voltages with different ordinal numbers, is not determined by the visual similarity or the degree of distortion of the load current waveforms relative to the supply voltage curve. 
461 |t Energies 
463 |t Vol. 14, iss. 16  |v [4814, 13 p.]  |d 2021 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a resource saving 
610 1 |a energy efficiency 
610 1 |a power quality capacitor bank 
610 1 |a current harmonics 
610 1 |a reactive power 
610 1 |a hybrid power filter 
610 1 |a active power filter 
610 1 |a экономия 
610 1 |a ресурсы 
610 1 |a энергоэффективность 
610 1 |a конденсаторы 
610 1 |a качество 
610 1 |a электроэнергия 
610 1 |a гармоники 
610 1 |a реактивные силы 
610 1 |a силовые фильтры 
701 1 |a Shchurov  |b N. I.  |g Nikolay Ivanovich 
701 1 |a Myatezh  |b S. V.  |g Sergey Vladimirovich 
701 1 |a Malozemov  |b B. V.  |g Boris Vitaljevich 
701 1 |a Shtang  |b A. A.  |g Aleksandr Aleksandrovich 
701 1 |a Martyushev  |b N. V.  |c specialist in the field of material science  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1981-  |g Nikita Vladimirovich  |3 (RuTPU)RU\TPU\pers\32906  |9 16754 
701 1 |a Klyuev  |b R. V.  |g Roman Vladimirovich 
701 1 |a Dedov  |b S. I.  |g Sergey Igorevich 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа новых производственных технологий  |b Отделение материаловедения  |3 (RuTPU)RU\TPU\col\23508 
801 2 |a RU  |b 63413507  |c 20211214  |g RCR 
856 4 |u http://earchive.tpu.ru/handle/11683/68963 
856 4 |u https://doi.org/10.3390/en14164814 