New Factors of Reliability of Electric Furnaces for Vermiculite Firing with Mobile Base Plates: Chap.; Progress in Material Science and Engineering; Vol. 351 : Studies in Systems, Decision and Control (SSDC)

Sonraí bibleagrafaíochta
Parent link:Progress in Material Science and Engineering/ eds. I. V. Minin, S. Uchaikin, A. Rogachev, O. Stary
Vol. 351 : Studies in Systems, Decision and Control (SSDC).— 2021.— [P. 125-138]
Údar corparáideach: Национальный исследовательский Томский политехнический университет Инженерная школа неразрушающего контроля и безопасности Отделение контроля и диагностики
Rannpháirtithe: Nizhegorodov A. I. Anatoliy Ivanovich, Gavrilin A. N. Aleksei Nikolaevich, Moyzes [Moises] B. B. Boris Borisovich, Kuvshinov K. A. Kirill Alexandrovich, Sakipova S. Saule
Achoimre:Title screen
The article reviews measures to increase the reliable operation of electric furnaces for vermiculite concentrates firing over the entire period of their existence since 2003. A significant step forward in this research was the find that the implementation of suspended heating systems in the electric modules of furnaces, both types such as modular-triggering furnaces and in furnaces with mobile base plates, where the swelling process of the raw material is carried out during the process of its vibrotransportation in the thermal field of the heating system. The imbalance of inertial loads is an additional factor for reducing of operation reliability in furnaces with mobile base plates. The methods of their balancing, discussed in this research, provide the dynamic balance of all moving parts of these furnace units. A study of analytical models of temperature distribution, carried out in previous researchers of the authors, showed that uniform heating can only be achieved in systems with a variable interval for the placement of heaters. The research results carried out in this work at the accepted values of the minimum and maximum intervals show that, compared to the old systems located on the refractory base of the firing modules, the difference temperature decreases significantly, which proves the effectiveness of this approach.
Режим доступа: по договору с организацией-держателем ресурса
Teanga:Béarla
Foilsithe / Cruthaithe: 2021
Ábhair:
Rochtain ar líne:https://doi.org/10.1007/978-3-030-68103-6_12
Formáid: MixedMaterials Leictreonach Caibidil leabhair
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=665602

MARC

LEADER 00000naa0a2200000 4500
001 665602
005 20250818130350.0
035 |a (RuTPU)RU\TPU\network\36802 
035 |a RU\TPU\network\36520 
090 |a 665602 
100 |a 20211022d2021 k||y0engy50 ba 
101 0 |a eng 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a New Factors of Reliability of Electric Furnaces for Vermiculite Firing with Mobile Base Plates  |e Chap.  |f A. I. Nizhegorodov, A. N. Gavrilin, B. B. Moyzes [Moises] [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 30 tit.] 
330 |a The article reviews measures to increase the reliable operation of electric furnaces for vermiculite concentrates firing over the entire period of their existence since 2003. A significant step forward in this research was the find that the implementation of suspended heating systems in the electric modules of furnaces, both types such as modular-triggering furnaces and in furnaces with mobile base plates, where the swelling process of the raw material is carried out during the process of its vibrotransportation in the thermal field of the heating system. The imbalance of inertial loads is an additional factor for reducing of operation reliability in furnaces with mobile base plates. The methods of their balancing, discussed in this research, provide the dynamic balance of all moving parts of these furnace units. A study of analytical models of temperature distribution, carried out in previous researchers of the authors, showed that uniform heating can only be achieved in systems with a variable interval for the placement of heaters. The research results carried out in this work at the accepted values of the minimum and maximum intervals show that, compared to the old systems located on the refractory base of the firing modules, the difference temperature decreases significantly, which proves the effectiveness of this approach. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Progress in Material Science and Engineering  |f eds. I. V. Minin, S. Uchaikin, A. Rogachev, O. Stary 
463 |t Vol. 351 : Studies in Systems, Decision and Control (SSDC)  |v [P. 125-138]  |d 2021 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
701 1 |a Nizhegorodov  |b A. I.  |g Anatoliy Ivanovich 
701 1 |a Gavrilin  |b A. N.  |c Specialist in the field of mechanical engineering  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1960-  |g Aleksei Nikolaevich  |3 (RuTPU)RU\TPU\pers\33397  |9 17091 
701 1 |a Moyzes [Moises]  |b B. B.  |c specialist in the field of mechanical engineering  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1975-  |g Boris Borisovich  |3 (RuTPU)RU\TPU\pers\32979  |9 16824 
701 1 |a Kuvshinov  |b K. A.  |c specialist in the field of material science  |c Senior Lecturer of Tomsk Polytechnic University  |f 1983-  |g Kirill Alexandrovich  |3 (RuTPU)RU\TPU\pers\42378 
701 1 |a Sakipova  |b S.  |g Saule 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа неразрушающего контроля и безопасности  |b Отделение контроля и диагностики  |3 (RuTPU)RU\TPU\col\23584 
801 2 |a RU  |b 63413507  |c 20211022  |g RCR 
856 4 |u https://doi.org/10.1007/978-3-030-68103-6_12 
942 |c CF