Identification of digital relay protection measuring part elements using time of its tripping
| Parent link: | Przeglad Elektrotechniczny Vol. 96, iss. 10.— 2020.— [P. 71-75] |
|---|---|
| Corporate Authors: | , |
| Other Authors: | , , , , |
| Summary: | Title screen The main problem preventing the use of digital relay protection mathematical models for real devices setting up is the confidentiality of the information about its internal configuration. This mainly concerns the input circuits (measuring part) of the protection, the components of which introduce the most significant errors. In this case, an arbitrary choice of the configuration may lead to incorrect results. The identification of the internal structure by standard methods, in particular by a real interpolation method, cannot be carried out in practice, due to the need to have input and output signals. In this regard, the purpose of the research was to develop a method of identification according to the time for formation of tripping signal. Identical signals were transmitted to real device and mathematical model of protection. The starting point of the time reference was the moment when the input signal reached a threshold; the final point was the time of tripping command appearance, unlike similar studies, where the time was determined by the closure of the output relay contacts. The research was carried out for 144 different combinations of the measuring part elements: auxiliary converters, analog filters, digital finite impulse response filters. As a result, the combination in which the smallest deviation from the tripping time of the real device was observed in all studied modes was selected as the most ‘optimal’. Performing such comparisons is the main way to make the model closer to real protection. Режим доступа: по договору с организацией-держателем ресурса |
| Language: | English |
| Published: |
2020
|
| Subjects: | |
| Online Access: | https://doi.org/10.15199/48.2020.10.12 |
| Format: | Electronic Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=665170 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 665170 | ||
| 005 | 20250128135816.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\36369 | ||
| 035 | |a RU\TPU\network\33562 | ||
| 090 | |a 665170 | ||
| 100 | |a 20210826d2020 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Identification of digital relay protection measuring part elements using time of its tripping |f M. V. Andreev, A. A. Suvorov, A. B. Askarov [et al.] | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References.: 15 tit.] | ||
| 330 | |a The main problem preventing the use of digital relay protection mathematical models for real devices setting up is the confidentiality of the information about its internal configuration. This mainly concerns the input circuits (measuring part) of the protection, the components of which introduce the most significant errors. In this case, an arbitrary choice of the configuration may lead to incorrect results. The identification of the internal structure by standard methods, in particular by a real interpolation method, cannot be carried out in practice, due to the need to have input and output signals. In this regard, the purpose of the research was to develop a method of identification according to the time for formation of tripping signal. Identical signals were transmitted to real device and mathematical model of protection. The starting point of the time reference was the moment when the input signal reached a threshold; the final point was the time of tripping command appearance, unlike similar studies, where the time was determined by the closure of the output relay contacts. The research was carried out for 144 different combinations of the measuring part elements: auxiliary converters, analog filters, digital finite impulse response filters. As a result, the combination in which the smallest deviation from the tripping time of the real device was observed in all studied modes was selected as the most ‘optimal’. Performing such comparisons is the main way to make the model closer to real protection. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Przeglad Elektrotechniczny | ||
| 463 | |t Vol. 96, iss. 10 |v [P. 71-75] |d 2020 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a relay protection | |
| 610 | 1 | |a identification | |
| 610 | 1 | |a setting up | |
| 610 | 1 | |a mathematical simulation | |
| 610 | 1 | |a релейная защита | |
| 610 | 1 | |a установки | |
| 610 | 1 | |a математическое моделирование | |
| 610 | 1 | |a конфигурации | |
| 610 | 1 | |a цифровая защита | |
| 701 | 1 | |a Andreev |b M. V. |c specialist in the field of electric power engineering |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences |f 1987- |g Mikhail Vladimirovich |3 (RuTPU)RU\TPU\pers\35035 | |
| 701 | 1 | |a Suvorov |b A. A. |c specialist in the field of electric power engineering |c Associate Professor of Tomsk Polytechnic University, Candidate of Technical Sciences |f 1990- |g Aleksey Aleksandrovich |3 (RuTPU)RU\TPU\pers\35638 |9 18807 | |
| 701 | 1 | |a Askarov |b A. B. |c power industry specialist |c Research Engineer of Tomsk Polytechnic University |f 1994- |g Alisher Bakhramzhonovich |3 (RuTPU)RU\TPU\pers\43159 |9 21629 | |
| 701 | 1 | |a Kievets |b A. V. |c power industry specialist |c Research Engineer of Tomsk Polytechnic University |f 1993- |g Anton Vladimirovich |3 (RuTPU)RU\TPU\pers\43158 | |
| 701 | 1 | |a Rudnik |b V. E. |c Specialist in the field of electric power engineering |c Research Engineer of Tomsk Polytechnic University |f 1995- |g Vladimir Evgenevich |3 (RuTPU)RU\TPU\pers\42419 |9 21532 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Инженерная школа энергетики |b Научно-исследовательская лаборатория "Моделирование электроэнергетических систем" |3 (RuTPU)RU\TPU\col\23567 |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Инженерная школа энергетики |b Отделение электроэнергетики и электротехники |3 (RuTPU)RU\TPU\col\23505 |
| 801 | 2 | |a RU |b 63413507 |c 20210826 |g RCR | |
| 856 | 4 | |u https://doi.org/10.15199/48.2020.10.12 | |
| 942 | |c CF | ||