Influence of artefact correction and recording device type on the practical application of a non-linear heart rate variability biomarker for aerobic threshold determination; Sensors; Vol. 21, iss. 3

Bibliografiske detaljer
Parent link:Sensors
Vol. 21, iss. 3.— 2021.— [821, 15 p.]
Institution som forfatter: National Research Tomsk Polytechnic University
Andre forfattere: Rogers B. Bruce, Giles D. A. David, Draper N. Nick, Mourot L. Laurent, Gronwald T. Thomas
Summary:Title screen
Recent study points to the value of a non-linear heart rate variability (HRV) biomarker using detrended fluctuation analysis (DFA a1) for aerobic threshold determination (HRVT). Significance of recording artefact, correction methods and device bias on DFA a1 during exercise and HRVT is unclear. Gas exchange and HRV data were obtained from 17 participants during an incremental treadmill run using both ECG and Polar H7 as recording devices. First, artefacts were randomly placed in the ECG time series to equal 1, 3 and 6% missed beats with correction by Kubios software's automatic and medium threshold method. Based on linear regression, Bland Altman analysis and Wilcoxon paired testing, there was bias present with increasing artefact quantity. Regardless of artefact correction method, 1 to 3% missed beat artefact introduced small but discernible bias in raw DFA a1 measurements. At 6% artefact using medium correction, proportional bias was found (maximum 19%). Despite this bias, the mean HRVT determination was within 1 bpm across all artefact levels and correction modalities. Second, the HRVT ascertained from synchronous ECG vs. Polar H7 recordings did show an average bias of minus 4 bpm. Polar H7 results suggest that device related bias is possible but in the reverse direction as artefact related bias.
Sprog:engelsk
Udgivet: 2021
Fag:
Online adgang:https://doi.org/10.3390/s21030821
Format: Electronisk Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=665137

MARC

LEADER 00000naa0a2200000 4500
001 665137
005 20250127162622.0
035 |a (RuTPU)RU\TPU\network\36336 
035 |a RU\TPU\network\36238 
090 |a 665137 
100 |a 20210824d2021 k||y0rusy50 ba 
101 0 |a eng 
102 |a CH 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Influence of artefact correction and recording device type on the practical application of a non-linear heart rate variability biomarker for aerobic threshold determination  |f B. Rogers, D. A. Giles, N. Draper [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 44 tit.] 
330 |a Recent study points to the value of a non-linear heart rate variability (HRV) biomarker using detrended fluctuation analysis (DFA a1) for aerobic threshold determination (HRVT). Significance of recording artefact, correction methods and device bias on DFA a1 during exercise and HRVT is unclear. Gas exchange and HRV data were obtained from 17 participants during an incremental treadmill run using both ECG and Polar H7 as recording devices. First, artefacts were randomly placed in the ECG time series to equal 1, 3 and 6% missed beats with correction by Kubios software's automatic and medium threshold method. Based on linear regression, Bland Altman analysis and Wilcoxon paired testing, there was bias present with increasing artefact quantity. Regardless of artefact correction method, 1 to 3% missed beat artefact introduced small but discernible bias in raw DFA a1 measurements. At 6% artefact using medium correction, proportional bias was found (maximum 19%). Despite this bias, the mean HRVT determination was within 1 bpm across all artefact levels and correction modalities. Second, the HRVT ascertained from synchronous ECG vs. Polar H7 recordings did show an average bias of minus 4 bpm. Polar H7 results suggest that device related bias is possible but in the reverse direction as artefact related bias. 
461 |t Sensors 
463 |t Vol. 21, iss. 3  |v [821, 15 p.]  |d 2021 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a heart rate variability 
610 1 |a detrended fluctuation analysis 
610 1 |a ventilatory threshold 
610 1 |a aerobic threshold 
610 1 |a intensity distribution 
610 1 |a artefact 
610 1 |a endurance exercise 
610 1 |a heart rate monitors 
610 1 |a wearables 
610 1 |a сердечные ритмы 
610 1 |a вариабельность 
610 1 |a интенсивность 
610 1 |a выносливость 
610 1 |a пульсометры 
610 1 |a биомаркеры 
610 1 |a нагрузки 
701 1 |a Rogers  |b B.  |g Bruce 
701 1 |a Giles  |b D. A.  |g David 
701 1 |a Draper  |b N.  |g Nick 
701 1 |a Mourot  |b L.  |c specialist in the field of physical training and sports  |c Senior Researcher of Tomsk Polytechnic University, Candidate of philological sciences  |f 1977-  |g Laurent  |3 (RuTPU)RU\TPU\pers\41001 
701 1 |a Gronwald  |b T.  |g Thomas 
712 0 2 |a National Research Tomsk Polytechnic University  |3 (RuTPU)RU\TPU\col\18773  |9 27197 
801 2 |a RU  |b 63413507  |c 20220624  |g RCR 
856 4 |u https://doi.org/10.3390/s21030821 
942 |c CF