Influence of artefact correction and recording device type on the practical application of a non-linear heart rate variability biomarker for aerobic threshold determination; Sensors; Vol. 21, iss. 3
| Parent link: | Sensors Vol. 21, iss. 3.— 2021.— [821, 15 p.] |
|---|---|
| Institution som forfatter: | |
| Andre forfattere: | , , , , |
| Summary: | Title screen Recent study points to the value of a non-linear heart rate variability (HRV) biomarker using detrended fluctuation analysis (DFA a1) for aerobic threshold determination (HRVT). Significance of recording artefact, correction methods and device bias on DFA a1 during exercise and HRVT is unclear. Gas exchange and HRV data were obtained from 17 participants during an incremental treadmill run using both ECG and Polar H7 as recording devices. First, artefacts were randomly placed in the ECG time series to equal 1, 3 and 6% missed beats with correction by Kubios software's automatic and medium threshold method. Based on linear regression, Bland Altman analysis and Wilcoxon paired testing, there was bias present with increasing artefact quantity. Regardless of artefact correction method, 1 to 3% missed beat artefact introduced small but discernible bias in raw DFA a1 measurements. At 6% artefact using medium correction, proportional bias was found (maximum 19%). Despite this bias, the mean HRVT determination was within 1 bpm across all artefact levels and correction modalities. Second, the HRVT ascertained from synchronous ECG vs. Polar H7 recordings did show an average bias of minus 4 bpm. Polar H7 results suggest that device related bias is possible but in the reverse direction as artefact related bias. |
| Sprog: | engelsk |
| Udgivet: |
2021
|
| Fag: | |
| Online adgang: | https://doi.org/10.3390/s21030821 |
| Format: | Electronisk Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=665137 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 665137 | ||
| 005 | 20250127162622.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\36336 | ||
| 035 | |a RU\TPU\network\36238 | ||
| 090 | |a 665137 | ||
| 100 | |a 20210824d2021 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a CH | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Influence of artefact correction and recording device type on the practical application of a non-linear heart rate variability biomarker for aerobic threshold determination |f B. Rogers, D. A. Giles, N. Draper [et al.] | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 44 tit.] | ||
| 330 | |a Recent study points to the value of a non-linear heart rate variability (HRV) biomarker using detrended fluctuation analysis (DFA a1) for aerobic threshold determination (HRVT). Significance of recording artefact, correction methods and device bias on DFA a1 during exercise and HRVT is unclear. Gas exchange and HRV data were obtained from 17 participants during an incremental treadmill run using both ECG and Polar H7 as recording devices. First, artefacts were randomly placed in the ECG time series to equal 1, 3 and 6% missed beats with correction by Kubios software's automatic and medium threshold method. Based on linear regression, Bland Altman analysis and Wilcoxon paired testing, there was bias present with increasing artefact quantity. Regardless of artefact correction method, 1 to 3% missed beat artefact introduced small but discernible bias in raw DFA a1 measurements. At 6% artefact using medium correction, proportional bias was found (maximum 19%). Despite this bias, the mean HRVT determination was within 1 bpm across all artefact levels and correction modalities. Second, the HRVT ascertained from synchronous ECG vs. Polar H7 recordings did show an average bias of minus 4 bpm. Polar H7 results suggest that device related bias is possible but in the reverse direction as artefact related bias. | ||
| 461 | |t Sensors | ||
| 463 | |t Vol. 21, iss. 3 |v [821, 15 p.] |d 2021 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a heart rate variability | |
| 610 | 1 | |a detrended fluctuation analysis | |
| 610 | 1 | |a ventilatory threshold | |
| 610 | 1 | |a aerobic threshold | |
| 610 | 1 | |a intensity distribution | |
| 610 | 1 | |a artefact | |
| 610 | 1 | |a endurance exercise | |
| 610 | 1 | |a heart rate monitors | |
| 610 | 1 | |a wearables | |
| 610 | 1 | |a сердечные ритмы | |
| 610 | 1 | |a вариабельность | |
| 610 | 1 | |a интенсивность | |
| 610 | 1 | |a выносливость | |
| 610 | 1 | |a пульсометры | |
| 610 | 1 | |a биомаркеры | |
| 610 | 1 | |a нагрузки | |
| 701 | 1 | |a Rogers |b B. |g Bruce | |
| 701 | 1 | |a Giles |b D. A. |g David | |
| 701 | 1 | |a Draper |b N. |g Nick | |
| 701 | 1 | |a Mourot |b L. |c specialist in the field of physical training and sports |c Senior Researcher of Tomsk Polytechnic University, Candidate of philological sciences |f 1977- |g Laurent |3 (RuTPU)RU\TPU\pers\41001 | |
| 701 | 1 | |a Gronwald |b T. |g Thomas | |
| 712 | 0 | 2 | |a National Research Tomsk Polytechnic University |3 (RuTPU)RU\TPU\col\18773 |9 27197 |
| 801 | 2 | |a RU |b 63413507 |c 20220624 |g RCR | |
| 856 | 4 | |u https://doi.org/10.3390/s21030821 | |
| 942 | |c CF | ||