Hybrid Real-Time Simulator for Setting of Automatic Secondary Frequency and Active Power Control; EEA - Electrotehnica, Electronica, Automatica; Vol. 68, iss. 2
| Parent link: | EEA - Electrotehnica, Electronica, Automatica Vol. 68, iss. 2.— 2020.— [P. 41-48] |
|---|---|
| Ente Autore: | |
| Altri autori: | , , , |
| Riassunto: | Title screen The results of the development of testing ground based on Hybrid real-time simulator for setting of automatic secondary frequency and active power control are presented. In the testing ground, the model of power system is realized in Hybrid real time power system simulator, while the model of automatic secondary frequency and active power control is realized in the MATLAB with Simulink® Desktop Real-Time™ software. The data exchange between the simulator and MATLAB/Simulink is realized by developing of the specialized software on the C# programming language. To confirm the adequacy of simulation, several simulation experiments of frequency and active power regulation under different disturbances were provided. In particular, power surge, which leads to an unbalance of active power, using different types of regulators of automatic secondary control of frequency and active power, were provided. According to the results, the occurred primary power imbalance leads to a decrease of frequency in the electric power system, which does not cause the action of emergency control automatic. During the process of frequency regulation, the generators and elements of the electric power system are loaded differently, depending on the types and settings of the regulators used. Accordingly, the appropriate setting of regulators can be carried out to correspond the requirements of standards. The obtained results show the proper operation of the testing ground and solve problems of modernization and verification of algorithms of automatic secondary control of frequency and active power. |
| Lingua: | inglese |
| Pubblicazione: |
2020
|
| Soggetti: | |
| Accesso online: | http://www.eea-journal.ro/ro/d/5/p/EEA68_2_5 |
| Natura: | MixedMaterials Elettronico Capitolo di libro |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=664973 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 664973 | ||
| 005 | 20250124144809.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\36158 | ||
| 090 | |a 664973 | ||
| 100 | |a 20210608d2020 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a RO | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Hybrid Real-Time Simulator for Setting of Automatic Secondary Frequency and Active Power Control |f R. A. Ufa, A. S. Vasilev, N. Yu. Ruban, V. E. Rudnik | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 23 tit.] | ||
| 330 | |a The results of the development of testing ground based on Hybrid real-time simulator for setting of automatic secondary frequency and active power control are presented. In the testing ground, the model of power system is realized in Hybrid real time power system simulator, while the model of automatic secondary frequency and active power control is realized in the MATLAB with Simulink® Desktop Real-Time™ software. The data exchange between the simulator and MATLAB/Simulink is realized by developing of the specialized software on the C# programming language. To confirm the adequacy of simulation, several simulation experiments of frequency and active power regulation under different disturbances were provided. In particular, power surge, which leads to an unbalance of active power, using different types of regulators of automatic secondary control of frequency and active power, were provided. According to the results, the occurred primary power imbalance leads to a decrease of frequency in the electric power system, which does not cause the action of emergency control automatic. During the process of frequency regulation, the generators and elements of the electric power system are loaded differently, depending on the types and settings of the regulators used. Accordingly, the appropriate setting of regulators can be carried out to correspond the requirements of standards. The obtained results show the proper operation of the testing ground and solve problems of modernization and verification of algorithms of automatic secondary control of frequency and active power. | ||
| 461 | |t EEA - Electrotehnica, Electronica, Automatica | ||
| 463 | |t Vol. 68, iss. 2 |v [P. 41-48] |d 2020 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a electric power system | |
| 610 | 1 | |a automatic secondary frequency and active power control | |
| 610 | 1 | |a simulation | |
| 610 | 1 | |a testing ground | |
| 610 | 1 | |a системы электроснабжения | |
| 610 | 1 | |a автоматический контроль | |
| 610 | 1 | |a моделирование | |
| 701 | 1 | |a Ufa |b R. A. |c specialist in the field of electric power engineering |c Associate Professor of Tomsk Polytechnic University, Candidate of Technical Sciences |f 1988- |g Ruslan Alexandrovich |3 (RuTPU)RU\TPU\pers\32883 |9 16731 | |
| 701 | 1 | |a Vasilev |b A. S. |c Specialist in the field of electric power engineering |c Associate Professor of Tomsk Polytechnic University, Candidate of Technical Sciences |f 1986- |g Alexey Sergeevich |3 (RuTPU)RU\TPU\pers\37859 |9 20550 | |
| 701 | 1 | |a Ruban |b N. Yu. |c specialist in the field of electric power engineering |c Associate Professor of Tomsk Polytechnic University, Candidate of Sciences |f 1988- |g Nikolay Yurievich |3 (RuTPU)RU\TPU\pers\34749 |9 18099 | |
| 701 | 1 | |a Rudnik |b V. E. |c Specialist in the field of electric power engineering |c Research Engineer of Tomsk Polytechnic University |f 1995- |g Vladimir Evgenevich |3 (RuTPU)RU\TPU\pers\42419 |9 21532 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Инженерная школа энергетики |b Отделение электроэнергетики и электротехники (ОЭЭ) |3 (RuTPU)RU\TPU\col\23505 |
| 801 | 2 | |a RU |b 63413507 |c 20210608 |g RCR | |
| 856 | 4 | |u http://www.eea-journal.ro/ro/d/5/p/EEA68_2_5 | |
| 942 | |c CF | ||