During room-and-pillar mining, protective pillars of coal are usually left standing. The protective pillars differ in shape, size, process properties and extractability ratios of coal. The authors propose a classification of the protective pillars with respect to their structure and shape in order to estimate and predict their properties. The extractability ratios of coal are calculated for the initial rib pillars and panels at different final shapes of protective pillars. The protective pillars are ranked with respects to the coal extractability ratios. Such systematization of pillars enables selecting the best engineering solutions and innovative improvement of room-and-pillar mining in specific geological conditions toward enhanced safety and efficiency of underground coal production.
Publicado em: 2020
Assuntos:
Acesso em linha:http://dx.doi.org/10.17580/em.2020.02.06
Formato: Recurso Electrónico Capítulo de Livro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=664412

MARC

LEADER 00000naa0a2200000 4500
001 664412
005 20250416091456.0
035 |a (RuTPU)RU\TPU\network\35596 
035 |a RU\TPU\network\33496 
090 |a 664412 
100 |a 20210413d2020 k||y0rusy50 ba 
102 |a RU 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Classification of protective pillars toward higher safety and innovation in room-and-pillar coal mining  |f S. A. Prokopenko, V. V. Sementsov, M. S. Dobrovolsky, E. V. Nifanov 
203 |a Текст  |c электронный 
300 |a Title screen 
320 |a [References: 19 tit.] 
330 |a During room-and-pillar mining, protective pillars of coal are usually left standing. The protective pillars differ in shape, size, process properties and extractability ratios of coal. The authors propose a classification of the protective pillars with respect to their structure and shape in order to estimate and predict their properties. The extractability ratios of coal are calculated for the initial rib pillars and panels at different final shapes of protective pillars. The protective pillars are ranked with respects to the coal extractability ratios. Such systematization of pillars enables selecting the best engineering solutions and innovative improvement of room-and-pillar mining in specific geological conditions toward enhanced safety and efficiency of underground coal production. 
461 |t Eurasian Mining 
463 |t № 2  |v [P. 24-27]  |d 2020 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a mine 
610 1 |a room-and-pillar mining 
610 1 |a rib pillar 
610 1 |a protective pillar 
610 1 |a cut 
610 1 |a cutter-loader 
610 1 |a extractability ratio 
610 1 |a losses 
610 1 |a classification 
610 1 |a shape 
701 1 |a Prokopenko  |b S. A.  |c mining engineer, economist  |c Professor of Tomsk Polytechnic University and Yurga technological Institute of Tomsk Polytechnic University, Doctor of technical sciences  |f 1959-  |g Sergey Arturovich  |3 (RuTPU)RU\TPU\pers\34648  |9 18010 
701 1 |a Sementsov  |b V. V.  |g Vyacheslav Vladimirovich 
701 1 |a Dobrovolsky  |b M. S. 
701 1 |a Nifanov  |b E. V. 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Юргинский технологический институт  |c (2009- )  |3 (RuTPU)RU\TPU\col\15903 
801 2 |a RU  |b 63413507  |c 20210413  |g RCR 
850 |a 63413507 
856 4 |u http://dx.doi.org/10.17580/em.2020.02.06 
942 |c CF