Flexible plasmonic graphene oxide/heterostructures for dual-channel detection; Analyst; Vol. 144, iss. 10

التفاصيل البيبلوغرافية
Parent link:Analyst
Vol. 144, iss. 10.— 2019.— [P. 3297-3306]
مؤلف مشترك: Национальный исследовательский Томский политехнический университет Исследовательская школа физики высокоэнергетических процессов
مؤلفون آخرون: Prakash V. Varnika, Rodriguez (Rodriges) Contreras R. D. Raul David, Al-Hamry A. Ammar, Lipovka A. A. Anna Anatolyevna, Dorozhko E. V. Elena Vladimirovna, Selyshchev O. Oleksandr, Ma Bing, Sharma S. Shweta, Mehta S. K. Surinder Kumar, Dzhagan V. Volodymyr, Mukherjee A. Ashutosh, Zahn Dietrich R. T., Kanoun O. Olfa, Sheremet E. S. Evgeniya Sergeevna
الملخص:Title screen
Graphene oxide (GO) films are deposited on flexible Kapton substrates and selectively modified to conductive reduced graphene oxide (rGO) electrodes using laser patterning. Based on this, we design, fabricate, and test a flexible sensor integrating laser-reduced GO with silver plasmonic nanostructures. The fabricated device results in dual transduction channels: for electrochemical and plasmonic nanostructure-based surface-enhanced Raman spectroscopy (SERS) detection. The spectroscopic analysis verifying the formation of rGO and the modification by silver nanostructures is performed by Raman, energy dispersive X-ray (EDX), and X-ray photoelectron spectroscopy (XPS). The morphological investigation is followed by optical and scanning electron microscopy imaging. In addition to pristine silver nanostructures, the Raman spectroscopy results show the formation of species such as Ag2O, Ag2CO3, and Ag2SOx. A dual-channel sensor device based on electrochemical and plasmonic detection is fabricated as a demonstration of our Ag–rGO flexible concept architecture. The dual-channel device performance is successfully demonstrated in the electrochemical and SERS detection of 4-nitrobenzenethiol (4-NBT) using the same device. Our results show that without Ag nanostructures the sensitivity in the electrochemical and optical channels is not sufficient to detect 4-NBT. The performance and stability of the silver modified device are also verified. This work demonstrates an inexpensive, highly efficient, and greener way that is compatible with solution-processing technology for the production of flexible GO-based electrochemical and SERS detection devices integrated with plasmonic nanostructures.
Режим доступа: по договору с организацией-держателем ресурса
اللغة:الإنجليزية
منشور في: 2019
الموضوعات:
الوصول للمادة أونلاين:https://doi.org/10.1039/C8AN02495B
التنسيق: الكتروني فصل الكتاب
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=664257

MARC

LEADER 00000naa0a2200000 4500
001 664257
005 20250915111946.0
035 |a (RuTPU)RU\TPU\network\35441 
090 |a 664257 
100 |a 20210405d2019 k||y0rusy50 ba 
101 0 |a eng 
102 |a GB 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Flexible plasmonic graphene oxide/heterostructures for dual-channel detection  |f V. Prakash, R. D. Rodriguez (Rodriges) Contreras, A. Al-Hamry [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 53 tit.] 
330 |a Graphene oxide (GO) films are deposited on flexible Kapton substrates and selectively modified to conductive reduced graphene oxide (rGO) electrodes using laser patterning. Based on this, we design, fabricate, and test a flexible sensor integrating laser-reduced GO with silver plasmonic nanostructures. The fabricated device results in dual transduction channels: for electrochemical and plasmonic nanostructure-based surface-enhanced Raman spectroscopy (SERS) detection. The spectroscopic analysis verifying the formation of rGO and the modification by silver nanostructures is performed by Raman, energy dispersive X-ray (EDX), and X-ray photoelectron spectroscopy (XPS). The morphological investigation is followed by optical and scanning electron microscopy imaging. In addition to pristine silver nanostructures, the Raman spectroscopy results show the formation of species such as Ag2O, Ag2CO3, and Ag2SOx. A dual-channel sensor device based on electrochemical and plasmonic detection is fabricated as a demonstration of our Ag–rGO flexible concept architecture. The dual-channel device performance is successfully demonstrated in the electrochemical and SERS detection of 4-nitrobenzenethiol (4-NBT) using the same device. Our results show that without Ag nanostructures the sensitivity in the electrochemical and optical channels is not sufficient to detect 4-NBT. The performance and stability of the silver modified device are also verified. This work demonstrates an inexpensive, highly efficient, and greener way that is compatible with solution-processing technology for the production of flexible GO-based electrochemical and SERS detection devices integrated with plasmonic nanostructures. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Analyst 
463 |t Vol. 144, iss. 10  |v [P. 3297-3306]  |d 2019 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
701 1 |a Prakash  |b V.  |g Varnika 
701 1 |a Rodriguez (Rodriges) Contreras  |b R. D.  |c Venezuelan physicist, doctor of science  |c Professor of Tomsk Polytechnic University  |f 1982-  |g Raul David  |3 (RuTPU)RU\TPU\pers\39942  |9 21179 
701 1 |a Al-Hamry  |b A.  |g Ammar 
701 1 |a Lipovka  |b A. A.  |c chemist  |c Associate Scientist of Tomsk Polytechnic University  |f 1993-  |g Anna Anatolyevna  |3 (RuTPU)RU\TPU\pers\44078  |9 21753 
701 1 |a Dorozhko  |b E. V.  |c chemist  |c Engineer of Tomsk Polytechnic University  |f 1979-  |g Elena Vladimirovna  |3 (RuTPU)RU\TPU\pers\32174  |9 16175 
701 1 |a Selyshchev  |b O.  |g Oleksandr 
701 0 |a Ma Bing 
701 1 |a Sharma  |b S.  |g Shweta 
701 1 |a Mehta  |b S. K.  |g Surinder Kumar 
701 1 |a Dzhagan  |b V.  |g Volodymyr 
701 1 |a Mukherjee  |b A.  |g Ashutosh 
701 1 |a Zahn Dietrich  |b R. T. 
701 1 |a Kanoun  |b O.  |g Olfa 
701 1 |a Sheremet  |b E. S.  |c physicist  |c Professor of Tomsk Polytechnic University  |f 1988-  |g Evgeniya Sergeevna  |3 (RuTPU)RU\TPU\pers\40027  |9 21197 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Исследовательская школа физики высокоэнергетических процессов  |c (2017- )  |3 (RuTPU)RU\TPU\col\23551 
801 0 |a RU  |b 63413507  |c 20210405  |g RCR 
850 |a 63413507 
856 4 |u https://doi.org/10.1039/C8AN02495B 
942 |c CF