X-Ray Microtomography Using Compensation Filters with Complicated Form
| Parent link: | Journal of Contemporary Physics (Armenian Academy of Sciences) Vol. 54, iss. 4.— 2019.— [P. 381-385] |
|---|---|
| Corporate Authors: | Национальный исследовательский Томский политехнический университет Исследовательская школа физики высокоэнергетических процессов, Национальный исследовательский Томский политехнический университет Физико-технический институт Кафедра прикладной физики (№ 12) Международная научно-образовательная лаборатория "Рентгеновская оптика", Национальный исследовательский Томский политехнический университет Инженерная школа природных ресурсов Отделение нефтегазового дела |
| Other Authors: | Chistyakov S. G. Sergey Gennadevich, Filatov N. A. Nikolay Alexandrovich, Kocharian (Kocharyan) V. R. Vagan Rashidovich, Gogolev A. S. Aleksey Sergeevich, Rukavishnikov V. S. Valery Sergeevich |
| Summary: | Title screen The influence of an aluminum compensation filter of complicated form on the signal-tonoise ratio in microtomography of geological cores was investigated. When scanning the core, a compensation filter in the form of an aluminum parallelepiped with a hole approximately equal to the diameter of the core was used. The filter is fixed rigid over the object table, the core is placed in the hole and rotates inside the filter. It is shown that the filter provides the maximal contrast of the useful signal over the entire dynamic range of the scintillation panel detector. After normalizing the projection of the core onto the filter projection without the core, the obtained projections were used in the standard reconstruction algorithm for cone beam tomography. The use of a compensation filter made it possible to increase the signal-to-noise ratio of the resulting tomograms by more than two times, as compared with the case of a conventional flat filter made of aluminum. Режим доступа: по договору с организацией-держателем ресурса |
| Published: |
2019
|
| Subjects: | |
| Online Access: | https://doi.org/10.3103/S106833721904008X |
| Format: | Electronic Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=663739 |
Similar Items
Theoretical study of a simplified implementation model of a dual-energy technique for computed tomography
Published: (2018)
Published: (2018)
Using a plane wave approximation in simulation of radiation distribution in an X-ray Talbot interferometer
Published: (2017)
Published: (2017)
Calculation Model of X-Ray Computed Tomography with Density Assessment Function
Published: (2021)
Published: (2021)
Effect of temperature gradient on parametric X-Ray radiation. Status of experiment
Published: (2015)
Published: (2015)
Bremsstrahlung converter system with target in vacuum
Published: (2021)
Published: (2021)
The formation of amplitude spectra in X-ray pixel detectors made of gallium arsenide
by: Ayzenshtat G. I.
Published: (2017)
by: Ayzenshtat G. I.
Published: (2017)
Effect of the Temperature Gradient on the X-ray Diffraction Spectrum of a Quartz Crystal
Published: (2017)
Published: (2017)
X-Ray Tomography Simulation Based on Direct Radon Transform
by: Ozdiev A. H. Ali Hosenovich
Published: (2017)
by: Ozdiev A. H. Ali Hosenovich
Published: (2017)
Quantum Theory of X-ray Radiation by Relativistic Electrons at Small-Angle Reflection from Crystals
by: Korotchenko K. B. Konstantin Borisovich
Published: (2018)
by: Korotchenko K. B. Konstantin Borisovich
Published: (2018)
On the Possibility of Two-Dimensional Focusing of Reflected X-Rays from Quartz Single Crystal in the Presence of External Temperature Gradient
by: Kocharian (Kocharyan) V. R. Vagan Rashidovich
Published: (2018)
by: Kocharian (Kocharyan) V. R. Vagan Rashidovich
Published: (2018)
Monochromatic X-ray sources based on a mechanism of real and virtual photon diffraction in crystals
Published: (2008)
Published: (2008)
The Mathematical Model of the Broadband Transmission X-Ray Thickness Gauge
Published: (2019)
Published: (2019)
The current state and prospects of X-ray computational tomography
Published: (2016)
Published: (2016)
The effect of low-temperature auto-ignition of W–Cu2O nanopowders with core-shell structure
by: Krinitsyn M. G. Maksim Germanovich
Published: (2022)
by: Krinitsyn M. G. Maksim Germanovich
Published: (2022)
Increasing the Number of Material Recognition Classes in Cargo Inspection Using the X-Ray Dual High-Energy Method
by: Osipov S. P. Sergey Pavlovich
Published: (2025)
by: Osipov S. P. Sergey Pavlovich
Published: (2025)
Algorithm for Evaluating Errors in Recognition of Materials in X-Ray Testing System Containing X-Ray Sandwich Detectors
by: Udod V. A. Viktor Anatolievich
Published: (2022)
by: Udod V. A. Viktor Anatolievich
Published: (2022)
Hard X-Ray diffraction in quartz single crystals in the presence of temperature gradient
by: Kocharyan V. R. Vagan Rashidovich
Published: (2017)
by: Kocharyan V. R. Vagan Rashidovich
Published: (2017)
Algorithms for Modeling the Formation and Processing of Information in X-Ray Tomography of Foam Materials
Published: (2021)
Published: (2021)
Parametric X-ray radiation and texture of polycrystalline foils
Published: (2018)
Published: (2018)
Parametric X-rays generated by electrons in multilayer mirrors mounted inside a betatron
Published: (2009)
Published: (2009)
Evaluation of porous structure by Kr and Xe desorption halftimes with X-Ray Fluorescence analysis
by: Ryzhkov V. A. Vladislav Andreevich
Published: (2022)
by: Ryzhkov V. A. Vladislav Andreevich
Published: (2022)
Digital X-Ray Apparatus Based on the Scanning R-Ray Gas-Discharge Detector for Studying of Interior Structure of Biological Objects
Published: (2014)
Published: (2014)
Soft X-Rays and Extreme Ultraviolet Radiation. Principles and Applications
by: Attwood D. David
Published: (New York, Cambridge University Press, 2007)
by: Attwood D. David
Published: (New York, Cambridge University Press, 2007)
Specific Features of Material Recognition by the Multi-Energy X-Ray Method
Published: (2019)
Published: (2019)
Optimization of Transmission X-ray Target for Intense Pulsed Electron Beam Accelerators
Published: (2022)
Published: (2022)
Оценка энергетической эффективности активных силовых фильтров для систем электроснабжения северных регионов
by: Дыбко М. А. Максим Александрович
Published: (2023)
by: Дыбко М. А. Максим Александрович
Published: (2023)
Portable Gamma-Ray Spectrometer for High Intensity Beam Measuring
Published: (2015)
Published: (2015)
X-rays from relativistic electrons crossing a multilayer nanostructure
Published: (2005)
Published: (2005)
Observation of soft X-ray Cherenkov radiation in Be and Si foils
by: Uglov S. R. Sergey Romanovich
Published: (2021)
by: Uglov S. R. Sergey Romanovich
Published: (2021)
Comparison of X-ray sources on the basis of bremsstrahlung and parametric radiations
by: Gogolev A. S. Aleksey Sergeevich
Published: (2007)
by: Gogolev A. S. Aleksey Sergeevich
Published: (2007)
Structural properties of luminescent ceramics YAG:CE investigated using X-ray
by: Ambarnikova N. V. Nataljya Vladimirovna
Published: (2023)
by: Ambarnikova N. V. Nataljya Vladimirovna
Published: (2023)
X-ray tomography in the study of rocks
by: Kochnev A. A.
Published: ()
by: Kochnev A. A.
Published: ()
Monochromatic X-Ray Source for Dual-Wave X-Ray Absorptiometry
Published: (2015)
Published: (2015)
Detecting unit for X-ray nondestructive testing systems
by: Nam I. F. Irina Feliksovna
Published: (2015)
by: Nam I. F. Irina Feliksovna
Published: (2015)
Radiation Burden Decline to the Objects in the X-Ray Investigation
Published: (2015)
Published: (2015)
Emission of quasi-monochromatic ultrasoft X-ray of multilayer target in the Bragg direction under 5.7 MeV electron irradiation
by: Uglov S. R. Sergey Romanovich
Published: (2024)
by: Uglov S. R. Sergey Romanovich
Published: (2024)
Making 3D model of atrioventricular xenopericardial bioprosthesis from X-ray computed tomography data
Published: (2016)
Published: (2016)
The relative error of calculations at the Pöschl-Teller model potential for the planar channeled muon
by: Li X. T.
Published: (2018)
by: Li X. T.
Published: (2018)
Estimation of the effective mass thickness and effective atomic number of the test object material by the dual energy method
Published: (2020)
Published: (2020)
Experimental setup on 5.7 MeV microtron for investigation of vacuum ultraviolet and ultrasoft X-ray radiations generated in multilayer mirror
by: Uglov S. R. Sergey Romanovich
Published: (2013)
by: Uglov S. R. Sergey Romanovich
Published: (2013)
Similar Items
-
Theoretical study of a simplified implementation model of a dual-energy technique for computed tomography
Published: (2018) -
Using a plane wave approximation in simulation of radiation distribution in an X-ray Talbot interferometer
Published: (2017) -
Calculation Model of X-Ray Computed Tomography with Density Assessment Function
Published: (2021) -
Effect of temperature gradient on parametric X-Ray radiation. Status of experiment
Published: (2015) -
Bremsstrahlung converter system with target in vacuum
Published: (2021)