A Simple Digital Thermometer; Instruments and Experimental Techniques; Vol. 63, iss. 3

Detalles Bibliográficos
Parent link:Instruments and Experimental Techniques
Vol. 63, iss. 3.— 2020.— [P. 348-350]
Autor Corporativo: Национальный исследовательский Томский политехнический университет Исследовательская школа физики высокоэнергетических процессов
Outros autores: Filatov A. V. Aleksandr Vladimirovich, Kobzev V. M. Vyacheslav Mikhaylovich, Filatov N. A. Nikolay Alexandrovich, Serdyukov K. A. Konstantin Alekseevich, Novikova A. A. Anastasiya Alekseevna
Summary:Title screen
A digital thermometer is described in which the use of a modified null method has significantly reduced the impact of changes in the gain of the measuring path on the measurement accuracy. Autoregulation of the zero balance in the thermometer is performed using two types of pulse modulation: amplitude and pulse-width. For a 12-bit digital output code and a measurement resolution of 0.037°С, the integral value of the nonlinearity error did not exceed ±0.1°С in the temperature range of 100–250°С.
Режим доступа: по договору с организацией-держателем ресурса
Idioma:inglés
Publicado: 2020
Subjects:
Acceso en liña:https://doi.org/10.1134/S0020441220030100
Formato: Electrónico Capítulo de libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=663096

MARC

LEADER 00000naa0a2200000 4500
001 663096
005 20250424093238.0
035 |a (RuTPU)RU\TPU\network\34265 
090 |a 663096 
100 |a 20210125d2020 k||y0rusy50 ba 
101 1 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a A Simple Digital Thermometer  |f A. V. Filatov, V. M. Kobzev, N. A. Filatov [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 4 tit.] 
330 |a A digital thermometer is described in which the use of a modified null method has significantly reduced the impact of changes in the gain of the measuring path on the measurement accuracy. Autoregulation of the zero balance in the thermometer is performed using two types of pulse modulation: amplitude and pulse-width. For a 12-bit digital output code and a measurement resolution of 0.037°С, the integral value of the nonlinearity error did not exceed ±0.1°С in the temperature range of 100–250°С. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Instruments and Experimental Techniques 
463 |t Vol. 63, iss. 3  |v [P. 348-350]  |d 2020 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a цифровые термометры 
610 1 |a измерения 
610 1 |a импульсная модуляция 
701 1 |a Filatov  |b A. V.  |g Aleksandr Vladimirovich 
701 1 |a Kobzev  |b V. M.  |g Vyacheslav Mikhaylovich 
701 1 |a Filatov  |b N. A.  |c Specialist in the field of automatic control  |c Engineer of Tomsk Polytechnic University  |f 1983-  |g Nikolay Alexandrovich  |3 (RuTPU)RU\TPU\pers\40863  |9 21352 
701 1 |a Serdyukov  |b K. A.  |g Konstantin Alekseevich 
701 1 |a Novikova  |b A. A.  |g Anastasiya Alekseevna 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Исследовательская школа физики высокоэнергетических процессов  |c (2017- )  |3 (RuTPU)RU\TPU\col\23551 
801 2 |a RU  |b 63413507  |c 20210125  |g RCR 
850 |a 63413507 
856 4 |u https://doi.org/10.1134/S0020441220030100 
942 |c CF