Soft X-ray diffraction patterns measured by a LiF detector with sub-micrometre resolution and an ultimate dynamic range; Journal of Synchrotron Radiation; Vol. 27, iss. 3

Bibliographic Details
Parent link:Journal of Synchrotron Radiation
Vol. 27, iss. 3.— 2020.— [625-632 p.]
Corporate Author: Национальный исследовательский Томский политехнический университет Институт неразрушающего контроля Международная научно-образовательная лаборатория неразрушающего контроля
Other Authors: Makarov S. Sergey, Pikuz S. Sergey, Ryazantsev S. Sergey, Pikuz T. Tatiana, Buzmakov A. Alexey, Rose M. Max, Lazarev S. V. Sergey Vladimirovich, Senkbeil T. Tobias, Von Gundlach A. Andreas, Stuhr S. Susan, Rumancev C. Christoph, Dzhigaev D. Dmitry, Skopintsev P. Petr, Zaluzhnyy I. Ivan, Viefhaus J. Jens
Summary:Title screen
The unique diagnostic possibilities of X-ray diffraction, small X-ray scattering and phase-contrast imaging techniques applied with high-intensity coherent X-ray synchrotron and X-ray free-electron laser radiation can only be fully realized if a sufficient dynamic range and/or spatial resolution of the detector is available. In this work, it is demonstrated that the use of lithium fluoride (LiF) as a photoluminescence (PL) imaging detector allows measuring of an X-ray diffraction image with a dynamic range of ~10⁷ within the sub-micrometre spatial resolution. At the PETRA III facility, the diffraction pattern created behind a circular aperture with a diameter of 5 µm irradiated by a beam with a photon energy of 500 eV was recorded on a LiF crystal. In the diffraction pattern, the accumulated dose was varied from 1.7 ˣ 10⁵ J cm⁻³ in the central maximum to 2 ˣ 10⁻² J cm⁻³ in the 16th maximum of diffraction fringes. The period of the last fringe was measured with 0.8 µm width. The PL response of the LiF crystal being used as a detector on the irradiation dose of 500 eV photons was evaluated. For the particular model of laser-scanning confocal microscope Carl Zeiss LSM700, used for the readout of the PL signal, the calibration dependencies on the intensity of photopumping (excitation) radiation (λ = 488 nm) and the gain have been obtained.
Language:English
Published: 2020
Subjects:
Online Access:https://doi.org/10.1107/S1600577520002192
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=663087

MARC

LEADER 00000naa0a2200000 4500
001 663087
005 20250424092912.0
035 |a (RuTPU)RU\TPU\network\34256 
035 |a RU\TPU\network\33757 
090 |a 663087 
100 |a 20210123d2020 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Soft X-ray diffraction patterns measured by a LiF detector with sub-micrometre resolution and an ultimate dynamic range  |f S. Makarov , S. Pikuz, S. Ryazantsev [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
330 |a The unique diagnostic possibilities of X-ray diffraction, small X-ray scattering and phase-contrast imaging techniques applied with high-intensity coherent X-ray synchrotron and X-ray free-electron laser radiation can only be fully realized if a sufficient dynamic range and/or spatial resolution of the detector is available. In this work, it is demonstrated that the use of lithium fluoride (LiF) as a photoluminescence (PL) imaging detector allows measuring of an X-ray diffraction image with a dynamic range of ~10⁷ within the sub-micrometre spatial resolution. At the PETRA III facility, the diffraction pattern created behind a circular aperture with a diameter of 5 µm irradiated by a beam with a photon energy of 500 eV was recorded on a LiF crystal. In the diffraction pattern, the accumulated dose was varied from 1.7 ˣ 10⁵ J cm⁻³ in the central maximum to 2 ˣ 10⁻² J cm⁻³ in the 16th maximum of diffraction fringes. The period of the last fringe was measured with 0.8 µm width. The PL response of the LiF crystal being used as a detector on the irradiation dose of 500 eV photons was evaluated. For the particular model of laser-scanning confocal microscope Carl Zeiss LSM700, used for the readout of the PL signal, the calibration dependencies on the intensity of photopumping (excitation) radiation (λ = 488 nm) and the gain have been obtained. 
461 |t Journal of Synchrotron Radiation 
463 |t Vol. 27, iss. 3  |v [625-632 p.]  |d 2020 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a diffraction patterns 
610 1 |a LiF detectors 
610 1 |a color centers 
610 1 |a дифракционные картины 
610 1 |a центры окраски 
610 1 |a детекторы LiF 
610 1 |a рентгеновское излучение 
610 1 |a лазеры 
610 1 |a X-Ray 
610 1 |a lasers 
701 1 |a Makarov  |b S.  |g Sergey 
701 1 |a Pikuz  |b S.  |g Sergey 
701 1 |a Ryazantsev  |b S.  |g Sergey 
701 1 |a Pikuz  |b T.  |g Tatiana 
701 1 |a Buzmakov  |b A.  |g Alexey 
701 1 |a Rose  |b M.  |g Max 
701 1 |a Lazarev  |b S. V.  |c physicist  |c engineer at Tomsk Polytechnic University  |f 1984-  |g Sergey Vladimirovich  |3 (RuTPU)RU\TPU\pers\35210  |9 18475 
701 1 |a Senkbeil  |b T.  |g Tobias 
701 1 |a Von Gundlach  |b A.  |g Andreas 
701 1 |a Stuhr  |b S.  |g Susan 
701 1 |a Rumancev  |b C.  |g Christoph 
701 1 |a Dzhigaev  |b D.  |g Dmitry 
701 1 |a Skopintsev  |b P.  |g Petr 
701 1 |a Zaluzhnyy  |b I.  |g Ivan 
701 1 |a Viefhaus  |b J.  |g Jens 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Институт неразрушающего контроля  |b Международная научно-образовательная лаборатория неразрушающего контроля  |3 (RuTPU)RU\TPU\col\19961 
801 2 |a RU  |b 63413507  |c 20210123  |g RCR 
850 |a 63413507 
856 4 |u https://doi.org/10.1107/S1600577520002192 
942 |c CF