Dielectric Losses in Hydrogen-Saturated VT1-0 Titanium Induced by Eddy Current Propagation
| Parent link: | Technical Physics Vol. 65, iss. 1.— 2020.— [P. 93-95] |
|---|---|
| Hlavní autor: | |
| Korporativní autor: | |
| Další autoři: | , |
| Shrnutí: | Title screen Dielectric loss tangent tan? in hydrogen-saturated VT1-0 titanium has been studied in the hydrogen concentration range 190–2000 ppm and eddy current frequency interval 200–1000 kHz. The frequency dependence of tan? has two distinct peaks indicating that hydrogen is nonuniformly distributed along the depth of the titanium sample. It is supposed that this approach can be used to determine the hydrogen concentration in hydrogen-saturated VT1-0 metal. Режим доступа: по договору с организацией-держателем ресурса |
| Vydáno: |
2020
|
| Témata: | |
| On-line přístup: | https://doi.org/10.1134/S1063784220010260 |
| Médium: | Elektronický zdroj Kapitola |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=662737 |
| Shrnutí: | Title screen Dielectric loss tangent tan? in hydrogen-saturated VT1-0 titanium has been studied in the hydrogen concentration range 190–2000 ppm and eddy current frequency interval 200–1000 kHz. The frequency dependence of tan? has two distinct peaks indicating that hydrogen is nonuniformly distributed along the depth of the titanium sample. It is supposed that this approach can be used to determine the hydrogen concentration in hydrogen-saturated VT1-0 metal. Режим доступа: по договору с организацией-держателем ресурса |
|---|---|
| DOI: | 10.1134/S1063784220010260 |