Development of medical capacitive coupling electrodes using the skin-electrode contact control; Sensor Review; Vol. 40, iss. 3

Chi tiết về thư mục
Parent link:Sensor Review
Vol. 40, iss. 3.— 2020.— [9 р.]
Tác giả của công ty: Национальный исследовательский Томский политехнический университет Инженерная школа неразрушающего контроля и безопасности Отделение электронной инженерии
Tác giả khác: Evtushenko G. S. Gennady Sergeevich, Lezhnina I. A. Inna Alekseevna, Morenets (Morenetz) A. I. Artem Igorevich, Pavlenko B. N. Boris Nikolaevich, Boyakhchyan A. A. Arman Arturovich, Torgaev S. N. Stanislav Nikolaevich, Nam I. F. Irina Feliksovna
Tóm tắt:Title screen
Purpose The purpose of this paper is the development and study of capacitive coupling electrodes with the ability to monitor the quality of the skin-electrode contact in the process of electrocardiogram (ECG) diagnostics. The study's scope embraces experimental identification of distortions contributed into the recorded ECG signal at various degrees of disturbance of the skin-electrode contact. Design/methodology/approach A capacitive coupling electrode is designed and manufactured. A large number of experiments was carried out to record ECG signals with different quality of the skin-electrode contact. Using spectral analysis, the characteristic distortions of the ECG signals in the event of contact disturbance are revealed. Findings It was found that the violation of the skin-electrode contact leads to significant deterioration in the recorded signal. In this case, the most severe distortions appear with various violations of the skin-electrode contact of two sensors in one lead. It has been experimentally shown that the developed sensor allows monitoring the quality of the contact, and therefore, improvement of the quality of signal registration, enabled by the use of bespoke processing algorithms. Practical implications These sensors will be used in personalized medicine devices and tele-ECG devices. Originality/value In this work, authors studied the effect of the skin-electrode contact of a capacitive electrode with the body on the quality of the recorded ECG signal. Based on the studies, the necessity of monitoring contact was shown to improve the quality of diagnostics provided by personalized medicine devices; the capacitive sensor with contact feedback was developed.
Режим доступа: по договору с организацией-держателем ресурса
Ngôn ngữ:Tiếng Anh
Được phát hành: 2020
Những chủ đề:
Truy cập trực tuyến:https://doi.org/10.1108/SR-11-2019-0289
Định dạng: xMaterials Điện tử Chương của sách
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=662348

MARC

LEADER 00000naa0a2200000 4500
001 662348
005 20250120161412.0
035 |a (RuTPU)RU\TPU\network\33485 
035 |a RU\TPU\network\33467 
090 |a 662348 
100 |a 20200717d2020 k||y0engy50 ba 
101 0 |a eng 
102 |a GB 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Development of medical capacitive coupling electrodes using the skin-electrode contact control  |f G. S. Evtushenko, I. A. Lezhnina, A. I. Morenets (Kuritsyn) [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
330 |a Purpose The purpose of this paper is the development and study of capacitive coupling electrodes with the ability to monitor the quality of the skin-electrode contact in the process of electrocardiogram (ECG) diagnostics. The study's scope embraces experimental identification of distortions contributed into the recorded ECG signal at various degrees of disturbance of the skin-electrode contact. Design/methodology/approach A capacitive coupling electrode is designed and manufactured. A large number of experiments was carried out to record ECG signals with different quality of the skin-electrode contact. Using spectral analysis, the characteristic distortions of the ECG signals in the event of contact disturbance are revealed. Findings It was found that the violation of the skin-electrode contact leads to significant deterioration in the recorded signal. In this case, the most severe distortions appear with various violations of the skin-electrode contact of two sensors in one lead. It has been experimentally shown that the developed sensor allows monitoring the quality of the contact, and therefore, improvement of the quality of signal registration, enabled by the use of bespoke processing algorithms. Practical implications These sensors will be used in personalized medicine devices and tele-ECG devices. Originality/value In this work, authors studied the effect of the skin-electrode contact of a capacitive electrode with the body on the quality of the recorded ECG signal. Based on the studies, the necessity of monitoring contact was shown to improve the quality of diagnostics provided by personalized medicine devices; the capacitive sensor with contact feedback was developed. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Sensor Review 
463 |t Vol. 40, iss. 3  |v [9 р.]  |d 2020 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a spectral analysis 
610 1 |a capacitive coupling electrodes 
610 1 |a electrocardiogram 
610 1 |a fast fourier transform 
610 1 |a isoline 
610 1 |a wet electrodes 
610 1 |a спектральный анализ 
610 1 |a электроды 
610 1 |a ЭКГ 
610 1 |a преобразование Фурье 
610 1 |a изолинии 
701 1 |a Evtushenko  |b G. S.  |c Doctor of Technical Sciences, Professor of Tomsk Polytechnic University (TPU)  |c Russian specialist in electrophysics  |f 1947-  |g Gennady Sergeevich  |3 (RuTPU)RU\TPU\pers\29009  |9 13729 
701 1 |a Lezhnina  |b I. A.  |c specialist in the field of non-destructive testing  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1984-  |g Inna Alekseevna  |3 (RuTPU)RU\TPU\pers\33635  |9 17291 
701 1 |a Morenets (Morenetz)  |b A. I.  |c specialist in the field of electronics  |c engineer of Tomsk Polytechnic University  |f 1997-  |g Artem Igorevich  |3 (RuTPU)RU\TPU\pers\46748  |9 22384 
701 1 |a Pavlenko  |b B. N.  |g Boris Nikolaevich 
701 1 |a Boyakhchyan  |b A. A.  |g Arman Arturovich 
701 1 |a Torgaev  |b S. N.  |c specialist in the field of electronics  |c associate Professor of Tomsk Polytechnic University, candidate of physico-mathematical Sciences  |f 1984-  |g Stanislav Nikolaevich  |3 (RuTPU)RU\TPU\pers\31663  |9 15800 
701 1 |a Nam  |b I. F.  |c specialist in the field of electrophysics  |c Associate Professor of Tomsk Polytechnic University,candidate of technical sciences  |f 1981-  |g Irina Feliksovna  |3 (RuTPU)RU\TPU\pers\33676  |9 17307 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа неразрушающего контроля и безопасности  |b Отделение электронной инженерии  |3 (RuTPU)RU\TPU\col\23507 
801 2 |a RU  |b 63413507  |c 20210205  |g RCR 
856 4 |u https://doi.org/10.1108/SR-11-2019-0289 
942 |c CF