Mathematical Models of Radiation Transparency of Test Objects When Using Sandwich X-Ray Radiation Detectors; Russian Journal of Nondestructive Testing; Vol. 56, iss. 2

Dades bibliogràfiques
Parent link:Russian Journal of Nondestructive Testing
Vol. 56, iss. 2.— 2020.— [P. 161-170]
Autor principal: Udod V. A. Viktor Anatolievich
Autor corporatiu: Национальный исследовательский Томский политехнический университет Институт неразрушающего контроля Российско-китайская научная лаборатория радиационного контроля и досмотра
Altres autors: Vorobeychikov S. E. Sergey Erikovich, Nazarenko S. Yu. Svetlana Yurjevna
Sumari:Title screen
A mathematical model of the output signals of an X-ray sandwich detector is presented. Based on this model, two mathematical models of the radiation transparency of the test object for a sandwich radiation detector have been developed. These models are the basis for a theoretical assessment of the accuracy of recognizing materials using the corresponding implementation scheme of the dual-energy method. The fundamental difference between the developed models is that one of them does and the other does not take into account statistical dependence between the output signals of the sandwich detector. Recommendations on the preference for using each of these models are given.
Режим доступа: по договору с организацией-держателем ресурса
Idioma:anglès
Publicat: 2020
Matèries:
Accés en línia:https://doi.org/10.1134/S1061830920020096
Format: Electrònic Capítol de llibre
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=662241

MARC

LEADER 00000naa0a2200000 4500
001 662241
005 20250408141129.0
035 |a (RuTPU)RU\TPU\network\33378 
090 |a 662241 
100 |a 20200617d2020 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Mathematical Models of Radiation Transparency of Test Objects When Using Sandwich X-Ray Radiation Detectors  |f V. A. Udod, S. E. Vorobeychikov, S. Yu. Nazarenko 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 23 tit.] 
330 |a A mathematical model of the output signals of an X-ray sandwich detector is presented. Based on this model, two mathematical models of the radiation transparency of the test object for a sandwich radiation detector have been developed. These models are the basis for a theoretical assessment of the accuracy of recognizing materials using the corresponding implementation scheme of the dual-energy method. The fundamental difference between the developed models is that one of them does and the other does not take into account statistical dependence between the output signals of the sandwich detector. Recommendations on the preference for using each of these models are given. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Russian Journal of Nondestructive Testing 
463 |t Vol. 56, iss. 2  |v [P. 161-170]  |d 2020 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a X-ray radiation 
610 1 |a inspection control 
610 1 |a effective atomic number 
610 1 |a material recognition 
610 1 |a dual-energy method 
610 1 |a sandwich detector 
610 1 |a рентгеновское излучение 
610 1 |a инспекционный контроль 
700 1 |a Udod  |b V. A.  |c specialist in the field of non-destructive testing  |c Leading researcher of Tomsk Polytechnic University, Doctor of technical sciences  |f 1959-  |g Viktor Anatolievich  |3 (RuTPU)RU\TPU\pers\35232 
701 1 |a Vorobeychikov  |b S. E.  |g Sergey Erikovich 
701 1 |a Nazarenko  |b S. Yu.  |g Svetlana Yurjevna 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Институт неразрушающего контроля  |b Российско-китайская научная лаборатория радиационного контроля и досмотра  |3 (RuTPU)RU\TPU\col\21551 
801 2 |a RU  |b 63413507  |c 20200617  |g RCR 
856 4 |u https://doi.org/10.1134/S1061830920020096 
942 |c CF