Fast and All-Optical Hydrogen Sensor Based on Gold-Coated Optical Fiber Functionalized with Metal–Organic Framework Layer; Langmuir; Vol. 4, iss. 12

গ্রন্থ-পঞ্জীর বিবরন
Parent link:Langmuir
Vol. 4, iss. 12.— 2019.— [P. 3133-3140]
সংস্থা লেখক: Национальный исследовательский Томский политехнический университет Исследовательская школа химических и биомедицинских технологий (ИШХБМТ)
অন্যান্য লেখক: Milyutina (Miliutina) E. V. Elena Vadimovna, Guselnikova O. A. Olga Andreevna, Chufistova S. Sofiia, Kolska Zd. Zdenka, Elashnikov R. Roman, Postnikov P. S. Pavel Sergeevich, Svorcik V. Vaclav, Lyutakov O. Oleksy
সংক্ষিপ্ত:Title screen
Remote detection of hydrogen, without the utilization of electronic component or elevated temperature, is one of the hot topics in the hydrogen technology and safety. In this work, the design and realization of the optical fiber-based hydrogen sensor with unique characteristics are proposed. The proposed sensor is based on the gold-coated multimode fiber, providing the plasmon properties, decorated by the IRMOF-20 layer with high selectivity and affinity toward hydrogen. The IRMOF-20 layer was grown by a surface-assisted technique, and its formation and properties were studied using X-ray photoelectron spectroscopy, Raman, X-ray diffraction, and Brunauer–Emmett–Teller techniques. Simultaneous ellipsometry results indicate the apparent changes of the refractive index of the IRMOF-20 layer due to hydrogen sorption. As results, the presence of hydrogen led to the pronounced changes of plasmon band wavelength position as well as its intensity increase. The proposed hydrogen sensors were favorably distinguished by a high response/recovery rate, excellent selectivity toward the hydrogen, very low temperature dependency, functionality at room or lower temperature, insensitivity toward the humidity, and the presence of CO2, CO, or NO2. Additionally, the proposed hydrogen sensor showed good reversibility, reproducibility, and long-term stability.
Режим доступа: по договору с организацией-держателем ресурса
ভাষা:ইংরেজি
প্রকাশিত: 2019
বিষয়গুলি:
অনলাইন ব্যবহার করুন:https://doi.org/10.1021/acssensors.9b01074
বিন্যাস: বৈদ্যুতিক গ্রন্থের অধ্যায়
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=661772

MARC

LEADER 00000naa0a2200000 4500
001 661772
005 20250522131148.0
035 |a (RuTPU)RU\TPU\network\32644 
035 |a RU\TPU\network\26598 
090 |a 661772 
100 |a 20200214d2019 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Fast and All-Optical Hydrogen Sensor Based on Gold-Coated Optical Fiber Functionalized with Metal–Organic Framework Layer  |f E. V. Milyutina, O. A. Guselnikova, S. Chufistova [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
330 |a Remote detection of hydrogen, without the utilization of electronic component or elevated temperature, is one of the hot topics in the hydrogen technology and safety. In this work, the design and realization of the optical fiber-based hydrogen sensor with unique characteristics are proposed. The proposed sensor is based on the gold-coated multimode fiber, providing the plasmon properties, decorated by the IRMOF-20 layer with high selectivity and affinity toward hydrogen. The IRMOF-20 layer was grown by a surface-assisted technique, and its formation and properties were studied using X-ray photoelectron spectroscopy, Raman, X-ray diffraction, and Brunauer–Emmett–Teller techniques. Simultaneous ellipsometry results indicate the apparent changes of the refractive index of the IRMOF-20 layer due to hydrogen sorption. As results, the presence of hydrogen led to the pronounced changes of plasmon band wavelength position as well as its intensity increase. The proposed hydrogen sensors were favorably distinguished by a high response/recovery rate, excellent selectivity toward the hydrogen, very low temperature dependency, functionality at room or lower temperature, insensitivity toward the humidity, and the presence of CO2, CO, or NO2. Additionally, the proposed hydrogen sensor showed good reversibility, reproducibility, and long-term stability. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Langmuir 
463 |t Vol. 4, iss. 12  |v [P. 3133-3140]  |d 2019 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a plasmon 
610 1 |a optical fiber 
610 1 |a surface grafting 
610 1 |a metal-organic framework 
610 1 |a hydrogen detection 
610 1 |a плазмоны 
610 1 |a оптоволокно 
610 1 |a металлоорганические соединения 
610 1 |a водород 
701 1 |a Milyutina (Miliutina)  |b E. V.  |c chemical technologist  |c engineer of Tomsk Polytechnic University  |f 1991-  |g Elena Vadimovna  |3 (RuTPU)RU\TPU\pers\46756 
701 1 |a Guselnikova  |b O. A.  |c chemist  |c Researcher at Tomsk Polytechnic University, Candidate of Chemical Sciences  |f 1992-  |g Olga Andreevna  |3 (RuTPU)RU\TPU\pers\34478  |9 17861 
701 1 |a Chufistova  |b S.  |g Sofiia 
701 1 |a Kolska  |b Zd.  |g Zdenka 
701 1 |a Elashnikov  |b R.  |g Roman 
701 1 |a Postnikov  |b P. S.  |c organic chemist  |c Associate Professor of Tomsk Polytechnic University, Candidate of chemical sciences  |f 1984-  |g Pavel Sergeevich  |3 (RuTPU)RU\TPU\pers\31287  |9 15465 
701 1 |a Svorcik  |b V.  |g Vaclav 
701 1 |a Lyutakov  |b O.  |c chemist-technologist  |c Associate Scientist of Tomsk Polytechnic University  |f 1982-  |g Oleksy  |3 (RuTPU)RU\TPU\pers\36875 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Исследовательская школа химических и биомедицинских технологий (ИШХБМТ)  |c (2017- )  |3 (RuTPU)RU\TPU\col\23537 
801 2 |a RU  |b 63413507  |c 20210205  |g RCR 
850 |a 63413507 
856 4 |u https://doi.org/10.1021/acssensors.9b01074 
942 |c CF