Electrical discharge drilling of granite with positive and negative polarity of voltage pulses

Détails bibliographiques
Parent link:International Journal of Rock Mechanics and Mining Sciences
Vol. 123.— 2019.— [104058, 7 р.]
Collectivités auteurs: Национальный исследовательский Томский политехнический университет Инженерная школа новых производственных технологий Научно-производственная лаборатория "Импульсно-пучковых, электроразрядных и плазменных технологий", Национальный исследовательский Томский политехнический университет Инженерная школа новых производственных технологий Отделение материаловедения, Национальный исследовательский Томский политехнический университет Инженерная школа энергетики Отделение электроэнергетики и электротехники (ОЭЭ)
Autres auteurs: Yudin A. S. Artem Sergeevich, Zhurkov M. Yu. Mikhail Yurievich, Martemyanov S. M. Sergey Mikhailovich, Datskevich S. Yu. Sergey Yurievich, Vazhov (Vajov) V. F. Vladislav Fedorovich
Résumé:Title screen
Electrical discharge drilling is a promising method that allows for the reduction of the costs of well drilling in hard rocks including the energy costs. This paper describes experimental drilling of a well in granite. The well has the diameter of 340 mm and the depth of 15 m, and transformer oil was used as the drilling fluid. In order to study the characteristics of the drilling process and drill string stability we used two drill bits with the interelectrode gaps of 40 mm and 70 mm and applied pulse voltage of positive and negative polarity to the drill bit electrodes. The results are as follows. Increasing the inter-electrode gap has allowed us to reduce the energy costs while increasing the drilling rate, but it has slightly reduced the lifetime of the drill string insulation. The polarity of the voltage pulse has no effect on the penetration rate. At the same time, in the case of negative pulse polarity, the electrical stability of the drill string insulation is higher than that for the positive one. For the 70 mm inter-electrode drill gap, the specific energy consumption and energy input per unit length of the inter-electrode gap are lower while the performance of a single pulse is greater. In this paper we are also discussing the peculiarities and prospects of industrial implementation of electrical discharge drilling. In addition to increasing the overall reliability of the drill string and pulse power source, it is necessary to find suitable insulation material with high flashover resistance in water-based mud.
Режим доступа: по договору с организацией-держателем ресурса
Langue:anglais
Publié: 2019
Sujets:
Accès en ligne:https://doi.org/10.1016/j.ijrmms.2019.104058
Format: Électronique Chapitre de livre
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=660754

MARC

LEADER 00000naa0a2200000 4500
001 660754
005 20250514120039.0
035 |a (RuTPU)RU\TPU\network\30739 
035 |a RU\TPU\network\30726 
090 |a 660754 
100 |a 20191017d2019 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Electrical discharge drilling of granite with positive and negative polarity of voltage pulses  |f A. S. Yudin [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
330 |a Electrical discharge drilling is a promising method that allows for the reduction of the costs of well drilling in hard rocks including the energy costs. This paper describes experimental drilling of a well in granite. The well has the diameter of 340 mm and the depth of 15 m, and transformer oil was used as the drilling fluid. In order to study the characteristics of the drilling process and drill string stability we used two drill bits with the interelectrode gaps of 40 mm and 70 mm and applied pulse voltage of positive and negative polarity to the drill bit electrodes. The results are as follows. Increasing the inter-electrode gap has allowed us to reduce the energy costs while increasing the drilling rate, but it has slightly reduced the lifetime of the drill string insulation. The polarity of the voltage pulse has no effect on the penetration rate. At the same time, in the case of negative pulse polarity, the electrical stability of the drill string insulation is higher than that for the positive one. For the 70 mm inter-electrode drill gap, the specific energy consumption and energy input per unit length of the inter-electrode gap are lower while the performance of a single pulse is greater. In this paper we are also discussing the peculiarities and prospects of industrial implementation of electrical discharge drilling. In addition to increasing the overall reliability of the drill string and pulse power source, it is necessary to find suitable insulation material with high flashover resistance in water-based mud. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t International Journal of Rock Mechanics and Mining Sciences 
463 |t Vol. 123  |v [104058, 7 р.]  |d 2019 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a electrical discharge drilling 
610 1 |a pulse polarity 
610 1 |a granite 
610 1 |a borehole 
610 1 |a rate of penetration 
610 1 |a электроразрядное бурение 
610 1 |a импульсная полярность 
610 1 |a гранит 
610 1 |a скорость 
610 1 |a проникновение 
701 1 |a Yudin  |b A. S.  |c specialist in the field of electrophysics  |c researcher of Tomsk Polytechnic University, candidate of technical sciences  |f 1984-  |g Artem Sergeevich  |3 (RuTPU)RU\TPU\pers\33778  |9 17376 
701 1 |a Zhurkov  |b M. Yu.  |c electrophysicist  |c Research scientist of Tomsk Polytechnic University  |f 1978-  |g Mikhail Yurievich  |3 (RuTPU)RU\TPU\pers\32302 
701 1 |a Martemyanov  |b S. M.  |c specialist in the field of electronics  |c Associate Professor of Tomsk Polytechnic University, Candidate of Technical Sciences  |f 1986-  |g Sergey Mikhailovich  |3 (RuTPU)RU\TPU\pers\33787  |9 17385 
701 1 |a Datskevich  |b S. Yu.  |c electrophysicist  |c Associate Scientist of Tomsk Polytechnic University  |f 1981-  |g Sergey Yurievich  |3 (RuTPU)RU\TPU\pers\32303  |9 16279 
701 1 |a Vazhov (Vajov)  |b V. F.  |c specialist in the field of power engineering  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1939-  |g Vladislav Fedorovich  |3 (RuTPU)RU\TPU\pers\32301 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа новых производственных технологий  |b Научно-производственная лаборатория "Импульсно-пучковых, электроразрядных и плазменных технологий"  |3 (RuTPU)RU\TPU\col\23502 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа новых производственных технологий  |b Отделение материаловедения  |3 (RuTPU)RU\TPU\col\23508 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа энергетики  |b Отделение электроэнергетики и электротехники (ОЭЭ)  |3 (RuTPU)RU\TPU\col\23505 
801 2 |a RU  |b 63413507  |c 20191017  |g RCR 
850 |a 63413507 
856 4 |u https://doi.org/10.1016/j.ijrmms.2019.104058 
942 |c CF