Optimized Filtered Back-Projection Tomographic Reconstruction Algorithm for the Step-Shift Scanning of a Sample; Research in Nondestructive Evaluation; Vol. 30, iss. 3
| Parent link: | Research in Nondestructive Evaluation Vol. 30, iss. 3.— 2019.— [9 p.] |
|---|---|
| Auteur principal: | |
| Collectivités auteurs: | , |
| Autres auteurs: | , |
| Résumé: | Title screen The variety of modern X-ray sources opens possibilities to conduct measurements of a wide range of different specimens. The range includes objects with various properties such as the density, the amount and types of defects, and the size which can significantly change from sample to sample. Due to the development of portable high energy X-ray sources like betatrons, it is now possible to investigate objects of big sizes. Although, the fact that the dimensions of such objects can exceed the dimensions of X-ray setups requires to develop new types of scanning geometries and to adopt the algorithms of reconstruction and visualization. The scanning of an object along its longest dimension is one of the ways for investigating such objects. In this article, we present the step-shift scanning approach and the adaptation of filtered back-projection algorithm for this type of measurement. The developed algorithm allows to obtain the visualization of the whole volume of the object from the combination of all scanning steps or to visualize the separate parts of the object from the truncated dataset. Режим доступа: по договору с организацией-держателем ресурса |
| Langue: | anglais |
| Publié: |
2019
|
| Sujets: | |
| Accès en ligne: | https://doi.org/10.1080/09349847.2018.1498960 |
| Format: | Électronique Chapitre de livre |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=659512 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 659512 | ||
| 005 | 20250321163153.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\28093 | ||
| 035 | |a RU\TPU\network\28056 | ||
| 090 | |a 659512 | ||
| 100 | |a 20190222d2019 k||z0rusy50 ba | ||
| 101 | 1 | |a eng | |
| 135 | |a argn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Optimized Filtered Back-Projection Tomographic Reconstruction Algorithm for the Step-Shift Scanning of a Sample |f A. H. Ozdiev, B. K. Afornu, D. A. Sednev | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 12 tit.] | ||
| 330 | |a The variety of modern X-ray sources opens possibilities to conduct measurements of a wide range of different specimens. The range includes objects with various properties such as the density, the amount and types of defects, and the size which can significantly change from sample to sample. Due to the development of portable high energy X-ray sources like betatrons, it is now possible to investigate objects of big sizes. Although, the fact that the dimensions of such objects can exceed the dimensions of X-ray setups requires to develop new types of scanning geometries and to adopt the algorithms of reconstruction and visualization. The scanning of an object along its longest dimension is one of the ways for investigating such objects. In this article, we present the step-shift scanning approach and the adaptation of filtered back-projection algorithm for this type of measurement. The developed algorithm allows to obtain the visualization of the whole volume of the object from the combination of all scanning steps or to visualize the separate parts of the object from the truncated dataset. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Research in Nondestructive Evaluation | ||
| 463 | |t Vol. 30, iss. 3 |v [9 p.] |d 2019 | ||
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a X-Ray tomography | |
| 610 | 1 | |a non-destructive testing | |
| 610 | 1 | |a reconstruction algorithm | |
| 610 | 1 | |a scanning approach | |
| 610 | 1 | |a рентгеновская томография | |
| 610 | 1 | |a неразрушающий контроль | |
| 610 | 1 | |a реконструкция | |
| 610 | 1 | |a сканирование | |
| 700 | 1 | |a Ozdiev |b A. H. |c physicist |c design engineer at Tomsk Polytechnic University |f 1990- |g Ali Hosenovich |3 (RuTPU)RU\TPU\pers\37253 | |
| 701 | 1 | |a Afornu |b B. K. |c Specialist in the field of nuclear technologies |c Engineer of Tomsk Polytechnic University |f 1989- |g Bright Kwame |3 (RuTPU)RU\TPU\pers\46933 | |
| 701 | 1 | |a Sednev |b D. A. |c specialist in the field of non-destructive testing |c assistant of Tomsk Polytechnic University, Associate Scientist |f 1989- |g Dmitry Andreevich |3 (RuTPU)RU\TPU\pers\34514 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Институт неразрушающего контроля (ИНК) |b Международная научно-образовательная лаборатория неразрушающего контроля (МНОЛ НК) |3 (RuTPU)RU\TPU\col\19961 |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Инженерная школа ядерных технологий |b Отделение экспериментальной физики |3 (RuTPU)RU\TPU\col\23549 |
| 801 | 2 | |a RU |b 63413507 |c 20210811 |g PSBO | |
| 856 | 4 | |u https://doi.org/10.1080/09349847.2018.1498960 | |
| 942 | |c CF | ||