Evaluating damage of reinforced concrete structures subjected to bending using the parameters of electric response to mechanical impact

מידע ביבליוגרפי
Parent link:Composites Part B: Engineering: Scientific Journal
Vol. 158.— 2019.— [P. 34-45]
מחבר תאגידי: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Проблемная научно-исследовательская лаборатория электроники, диэлектриков и полупроводников (ПНИЛ ЭДиП)
מחברים אחרים: Fursa T. V. Tatyana Viktorovna, Petrov M. V. Maksim Vyacheslavovich, Dann D. D. Denis Dmitrievich, Reutov Yu. A. Yury Anatoljevich
סיכום:Title screen
The paper considers a method for evaluation of reinforced concrete damage due to the bending of concrete beams reinforced with steel and fiberglass reinforcement. The evaluation procedure is based on measuring the electrical response to mechanical impact. Measurements of the electrical response are carried out periodically during a gradual increase in the external load. The analysis of signals in time and frequency is the basis for the algorithm for evaluating the damage processes in reinforced concrete structures subjected to four-point bending. On the basis of numerical simulation and experimental study of the load graphs, the stages of damage process in reinforced concrete beams under bending action were determined. A good correspondence between experimental and theoretical results is shown. As diagnostic parameters characterizing the stages of damage in reinforced concrete beams, it is proposed to use the energy decay coefficient of the electrical responses, the coefficient of cross-correlation of the signal spectrum in the process of loading with the signal spectrum from the same sample before loading, and the frequency shift at which the maximum coefficient of correlation can be observed. Most informative frequency ranges where the proposed diagnostic parameters relation to the degradation processes of reinforced concrete during bending is more reliable were determined. The proposed method can be used to monitor the development of damage in reinforced concrete under bending conditions.
Режим доступа: по договору с организацией-держателем ресурса
שפה:אנגלית
יצא לאור: 2019
נושאים:
גישה מקוונת:https://doi.org/10.1016/j.compositesb.2018.09.042
פורמט: אלקטרוני Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=659151

MARC

LEADER 00000naa0a2200000 4500
001 659151
005 20250306162220.0
035 |a (RuTPU)RU\TPU\network\27602 
090 |a 659151 
100 |a 20190123d2019 k||y0rusy50 ba 
101 1 |a eng 
102 |a US 
135 |a drnn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Evaluating damage of reinforced concrete structures subjected to bending using the parameters of electric response to mechanical impact  |f T. V. Fursa [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 61 tit.] 
330 |a The paper considers a method for evaluation of reinforced concrete damage due to the bending of concrete beams reinforced with steel and fiberglass reinforcement. The evaluation procedure is based on measuring the electrical response to mechanical impact. Measurements of the electrical response are carried out periodically during a gradual increase in the external load. The analysis of signals in time and frequency is the basis for the algorithm for evaluating the damage processes in reinforced concrete structures subjected to four-point bending. On the basis of numerical simulation and experimental study of the load graphs, the stages of damage process in reinforced concrete beams under bending action were determined. A good correspondence between experimental and theoretical results is shown. As diagnostic parameters characterizing the stages of damage in reinforced concrete beams, it is proposed to use the energy decay coefficient of the electrical responses, the coefficient of cross-correlation of the signal spectrum in the process of loading with the signal spectrum from the same sample before loading, and the frequency shift at which the maximum coefficient of correlation can be observed. Most informative frequency ranges where the proposed diagnostic parameters relation to the degradation processes of reinforced concrete during bending is more reliable were determined. The proposed method can be used to monitor the development of damage in reinforced concrete under bending conditions. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 1 |t Composites Part B: Engineering  |o Scientific Journal 
463 1 |t Vol. 158  |v [P. 34-45]  |d 2019 
610 1 |a труды учёных ТПУ 
610 1 |a электронный ресурс 
610 1 |a стекловолокна 
610 1 |a механические свойства 
610 1 |a численный анализ 
610 1 |a неразрушающий контроль 
610 1 |a железобетон 
701 1 |a Fursa  |b T. V.  |c specialist in the field of non-destructive testing  |c Leading researcher of Tomsk Polytechnic University, Doctor of technical sciences  |f 1951-  |g Tatyana Viktorovna  |3 (RuTPU)RU\TPU\pers\32190 
701 1 |a Petrov  |b M. V.  |c specialist in the field of non-destructive testing  |c Associate Scientist of Tomsk Polytechnic University  |f 1992-  |g Maksim Vyacheslavovich  |3 (RuTPU)RU\TPU\pers\36439 
701 1 |a Dann  |b D. D.  |c specialist in the field of electrical engineering  |c Engineer-researcher of Tomsk Polytechnic University  |f 1987-  |g Denis Dmitrievich  |3 (RuTPU)RU\TPU\pers\32192 
701 1 |a Reutov  |b Yu. A.  |g Yury Anatoljevich 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт неразрушающего контроля (ИНК)  |b Проблемная научно-исследовательская лаборатория электроники, диэлектриков и полупроводников (ПНИЛ ЭДиП)  |3 (RuTPU)RU\TPU\col\19033 
801 2 |a RU  |b 63413507  |c 20190123  |g RCR 
856 4 0 |u https://doi.org/10.1016/j.compositesb.2018.09.042 
942 |c CF